MaintainX Asset Hub logo
EnterprisePricing
Daikin

Daikin Indoor Unit Cooling Only Air Conditioner FTE50KV19

Need answers fast?
Explore the manual using AI.

Daikin Indoor Unit Cooling Only Air Conditioner FTE50KV19
Daikin Indoor Unit Cooling Only Air Conditioner FTE50KV19

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Indoor Unit Cooling Only Air Conditioner FTE50KV19

Daikin Indoor Unit Cooling Only Air Conditioner FTE50KV19

Create an account to install this asset package.

Maintenance Plans for Daikin Indoor Unit Cooling Only Air Conditioner Model FTE50KV19

Integrate maintenance plans directly into your work orders in MaintainX.

Air Filter Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Open the front panel.

Check mark

Release each air filter from the 2 hooks of the front panel.

Check mark

Remove the air filter by pulling out downward.

Check mark

The air filter is not marked for difference between the right and left sides. Insert the air filter with the “FRONT” mark faced up.

Check mark

When reassembling, insert the air filter along the guides.

Check mark

Be sure to fasten the hooks when installing the air filter.

Check mark

Remove the Titanium apatite photocatalytic air-purifying filter, if available, from the 5 hooks.

Check mark

The right and left filters are interchangeable. Some models have no Titanium apatite photocatalytic air-purifying filter.

Run this procedureArrow right

Fan Motor / Fan Rotor Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Remove the 2 screws

Check mark

Lift and remove the right side plate

Check mark

Remove the screw, and then the fan motor fixing plate

Check mark

Insert the fan motor allowing for approx. 5 mm (0.2 inch) of play

Check mark

Tighten the fan rotor screw until it stops. Then give the screw one more turn

Check mark

If the fan rotor rotates appropriately, tighten the screw completely

Check mark

Loosen the screw of the fan rotor

Check mark

Remove the fan motor

Run this procedureArrow right

Electrical Box Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Remove the screw, then the drip proof plate.

Check mark

Cut the clamp.

Check mark

Pull out the indoor heat exchanger thermistor.

Check mark

Remove the screw of the earth/ground wire.

Check mark

Remove the screw of the wire fixture.

Check mark

Remove the 4 screws of the connecting wires.

Check mark

The position of the indoor heat exchanger thermistor varies depending on the model. Be careful not to lose the clip of the thermistor.

Check mark

Disconnect the connector [S1].

Run this procedureArrow right

Vertical Blade ASSY Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

1. For auto-swing (right and left) models

Check mark

Some models have fan guards. Remove the fan guards beforehand.

Check mark

The unit has 3 sets of vertical blade ASSYs linked to one another with interlock rods.

Check mark

1) Release the right and left shafts.

Check mark

2) Unfasten the 3 hooks for each set of vertical blade ASSY (9 hooks).

Check mark

3) Pull the vertical blade ASSYs to the right and remove them.

Check mark

2. For models without autoswing (right and left)

Check mark

Each vertical blade ASSY has 5 or 6 fins which can not be replaced individually.

Run this procedureArrow right

Swing Motor Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

1. Remove the swing motor for horizontal blades.

Check mark

1) Remove the screw.

Check mark

2) Remove the swing motor.

Check mark

2. Remove the swing motor for vertical blades.

Check mark

Remove the swing shaft.

Check mark

1) Remove the swing shaft on the right side.

Check mark

2) Remove the 2 screws and detach the swing motor assembly.

Check mark

Some models do not have the swing motor assembly.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets