Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Outdoor Heat Pump RXL09QMVJU
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Power Supply Waveform Check
Warning: This check requires trained personnel with PPE!
Enter the power supply waveform measurement between No. 1 and No. 2 on the terminal strip
Is the power supply waveform a sine wave (Refer to Fig.1)?
Is there waveform disturbance near the zero-cross (Refer to sections circled in Fig.2)?
Upload a photo of the measured waveform
Sign off on the power supply waveform check
Electronic Expansion Valve Check
EV connector correctly connected to the PCB
Did the EV generate a latching sound after power cycle
Continuity confirmed using a multimeter after disconnecting the connector
Check the continuity between the pins
EV coil is not faulty
Outdoor unit PCB (main PCB) is not faulty
Sign off on the electronic expansion valve check
Inverter Analyzer Check
Characteristics
Inverter analyzer: RSUK0917C
If an abnormal stop occurs due to compressor startup failure or overcurrent output when using an inverter unit, it is difficult to judge whether the stop is caused by the compressor failure or some other failure (main PCB, power module, etc.). The inverter analyzer makes it possible to judge the cause of trouble easily and securely. Connect an inverter analyzer as a quasi-compressor instead of compressor and check the output of the inverter.
Operation Method
Step 1: Be sure to turn the power off.
Step 2: Install an inverter analyzer instead of a compressor.
Note: Make sure the charged voltage of the built-in smoothing electrolytic capacitor drops to 10 VDC or below before carrying out the service work.
(1) Remove the terminals from the compressor.
(2) Connect the terminals to the terminals of the inverter analyzer.
Thermistor Resistance Check
Warning: Disconnect the connector of thermistor ASSY from the PCB before proceeding
Enter the resistance value measured from the thermistor
Does the measured resistance value match the listed value?
If the measured resistance value does not match the listed value, the thermistor must be replaced.
To check the thermistor soldered on a PCB, disconnect the PCB from other PCB/parts
Enter the resistance value measured from the soldered thermistor
Does the measured resistance value match the listed value?
If the measured resistance value does not match the listed value, the thermistor must be replaced.
Sign off on the thermistor resistance check
Power Module Check
Warning: Ensure that the voltage between (+) and (–) of the power module is about 0 V before proceeding
Voltage between (+) and (–) of the power module is about 0 V
Disconnect the compressor harness connector from the outdoor unit PCB. To disengage the connector, press the protrusion on the connector
Compressor harness connector disconnected
Measure resistance between the terminals of the power module and the terminals of the compressor with a multimeter
Enter the resistance measurement
Evaluate the measurement results
Sign off on the power module check
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX