Daikin Indoor Unit Wall Mounted Type Air Conditioner FTX18WVJU9
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Power Supply Waveform Check
Warning: This check requires trained personnel with PPE!
Measure the power supply waveform between No. 1 and No. 2 on the terminal strip
Upload a photo of the measured waveform
Is the power supply waveform a sine wave?
Is there waveform disturbance near the zero-cross?
Sign off on the power supply waveform check
Electronic Expansion Valve Check
EV connector correctly connected to the PCB
EV generates a latching sound when power is turned off and on
Continuity confirmed when connector is disconnected and checked with a multimeter
Check the continuity between the pins
EV coil is not faulty
Outdoor unit PCB (main PCB) is not faulty
Sign off on the electronic expansion valve check
Inverter Analyzer Check
Warning: This procedure requires trained personnel with PPE!
Power turned off?
Install an inverter analyzer instead of a compressor
Charged voltage of the built-in smoothing electrolytic capacitor dropped to 10 VDC or below?
Terminals removed from the compressor?
Terminals connected to the terminals of the inverter analyzer without touching each other?
Activate the power transistor test operation from the outdoor unit
Power turned on?
Center of TEMP button and OFF button on the remote controller pressed at the same time?
Main Circuit Short Check
Warning: Ensure the voltage between (+) and (-) of the diode bridge (DB1) is about 0 V before proceeding
Enter the voltage between (+) and (-) of the diode bridge (DB1)
Is the voltage approximately 0 V?
If voltage is not approximately 0 V, stop the procedure and report the issue
Enter the resistance between the pins of the DB1
Is the resistance either infinity or less than 1 kΩ?
If resistance is not infinity or less than 1 kΩ, a short circuit occurs on the main circuit
Sign off on the main circuit short check
Power Module Check
Warning: Ensure the voltage between (+) and (–) of the power module is about 0 V before proceeding
Enter the voltage reading between (+) and (–) of the power module
Disconnect the compressor harness connector from the outdoor unit PCB. To disengage the connector, press the protrusion on the connector.
Was the compressor harness connector successfully disconnected?
Measure resistance between the terminals of the power module and the terminals of the compressor with a multimeter.
Enter the resistance reading between the terminals of the power module and the terminals of the compressor
Evaluate the measurement results
Sign off on the power module check
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX