Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Indoor Unit Multi-Split Type Air Conditioner CTXG12QVJUW
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Inverter Analyzer Check
Warning: This procedure requires trained personnel with PPE!
Is the power turned off?
If power is not turned off, stop the procedure and turn off the power
Is the charged voltage of the built-in smoothing electrolytic capacitor 10 VDC or below?
If the charged voltage is above 10 VDC, wait until it drops to 10 VDC or below
Are the terminals from the compressor removed?
Are the terminals connected to the terminals of the inverter analyzer?
Warning: Do not let the terminals (U,V,W) touch each other. High voltage is applied.
Is the power transistor test operation activated from the outdoor unit?
Rotation Pulse Check
Outdoor fan motor
Voltage between the pins 4 - 7
Control voltage between the pins 4 - 3
Rotation command voltage between the pins 4 - 2
Pulses at the pins 4 - 1 when the outdoor fan motor is rotated 1 turn by hand
Fuse melted?
Outdoor fan motor functioning properly?
Defective PCB?
Defective Hall IC?
Capacitor Voltage Check
Warning: This procedure requires trained personnel with PPE!
Main circuit checked for short circuit?
Voltage between FU2 and DC–
Voltage 50 V or less?
Ensure firm contact between the multimeter probes and the test points.
Sign off on the capacitor voltage check
Power Supply Waveform Check
Warning: This check requires trained personnel with PPE!
Enter the power supply waveform measurement between No. 1 and No. 2 on the terminal board
Is the power supply waveform a sine wave as shown in Fig.1?
Is there any waveform disturbance near the zero-cross as shown in the sections circled in Fig.2?
Upload a photo of the measured waveform
Sign off on the power supply waveform check
Power Module Check
Warning: Ensure that the voltage between (+) and (–) of the power module is about 0 V before proceeding
Voltage between (+) and (–) of the power module is about 0 V
Disconnect the compressor harness connector from the outdoor unit PCB. To disengage the connector, press the protrusion on the connector.
Compressor harness connector disconnected from the outdoor unit PCB
Measure resistance between the (+) or (–) terminal of the power module and the U, V, or W terminal of the compressor with a multimeter.
Enter the resistance measurement
Evaluate the measurement results
Sign off on the power module check
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX