MaintainX Logo
EnterprisePricing
Daikin

Daikin Daikin Air Handler CAH004GDAM CAH004GDAM

Need answers fast?
Explore the manual using AI.

Daikin Daikin Air Handler CAH004GDAM CAH004GDAM
Daikin Daikin Air Handler CAH004GDAM CAH004GDAM

The Daikin Air Handler CAH004GDAM is a high-efficiency air handling unit designed for optimal indoor climate control. This model features advanced technology for reliable performance, ensuring effective air distribution and comfort in industrial applications. Ideal for various settings, it supports efficient heating and cooling solutions.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Daikin Air Handler CAH004GDAM CAH004GDAM

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Daikin Air Handler CAH004GDAM CAH004GDAM

Daikin Daikin Air Handler CAH004GDAM CAH004GDAM

Create an account to install this asset package.

Maintenance Plans for Daikin Daikin Air Handler CAH004GDAM Model CAH004GDAM

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Bub Replacement

Check mark

WARNING: Personal Injury Hazard. Power supply can cause electrical shock. Always disconnect all power to unit before servicing

Check mark

WARNING: UV-C exposure is harmful to the skin and eyes. Looking at an illuminated UV-C bulb can cause permanent blindness. UV-C skin exposure can cause cancer

Check mark

WARNING: Fluorescent bulbs contain mercury, which can cause personal injury if breathed or ingested. Use appropriate protective gear to clean up broken bulbs

Check mark

Verify the UV lights are off by using the view window

Check mark

Disconnect power to the power receptacle before servicing

Check mark

Verify the power is disconnected

Check mark

Before opening the access panels, use the viewing window to make sure the UV lights are off

Check mark

Before handling, allow bulbs to cool for 5 minutes

Check mark

Grasp body of bulb firmly at each end

Run this procedureArrow right

6 Monthly Air Handler Check

Check mark

Check all moving parts for wear

Check mark

Check bearing collar, sheave, and wheel hub setscrews, sheave capscrews, and bearing hold-down bolts for tightness

Check mark

Annually check and snug all electrical connections

Check mark

Inspect for signs of water damage such as corrosion and repair if necessary

Check mark

Check ground conductor and connection integrity and correct if needed

Run this procedureArrow right

6 Monthly Coil Maintenance

Check mark

Warning: This maintenance check requires trained personnel!

Check mark

Drain pans in any air conditioning unit may have some moisture.

Check mark

Presence of algae or bacteria growth in the drain pans?

Check mark

Periodic cleaning is necessary to prevent this buildup from plugging the drain and causing the drain pan to overflow.

Check mark

Also, keep the drain pans clean to prevent the spread of disease.

Check mark

Drain pans cleaned?

Check mark

Dirt and lint can clog the condensate drain, especially with dirty filters.

Check mark

Condensate drain inspected?

Check mark

Inspect twice a year to help avoid overflow.

Run this procedureArrow right

LVP Variable Speed Sheave Maintenance

Check mark

Belt tension slacked off if belts have been installed

Check mark

Setscrews D loosened

Check mark

Capscrews E loosened but not removed

Check mark

Key F removed

Check mark

Pitch diameter adjusted by opening or closing the movable flanges by half or full turns

Check mark

Key F replaced

Check mark

Setscrews D and capscrews E tightened

Check mark

Belt tension readjusted if belts have been installed, or belts installed and tension adjusted if not

Check mark

All keys in place and all setscrews and all capscrews are tight before starting the drive

Run this procedureArrow right

1 Weekly Fan Shaft Bearings Lubrication

Check mark

CAUTION: For safety, stop rotating equipment before lubrication

Check mark

Equipment stopped for lubrication?

Check mark

Enter the temperature after lubrication

Check mark

CAUTION: For best results, specific applications should be monitored regularly and lubrication intervals and amounts adjusted accordingly

Check mark

Type of grease used for lubrication

Check mark

Compatibility of grease checked?

Check mark

Lubrication Interval

Check mark

Recommended Lubricants for Fan Shaft Ball Bearings

Check mark

Sign off on the lubrication procedure

Run this procedureArrow right

Parts for Daikin Daikin Air Handler CAH004GDAM CAH004GDAM

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Replacement Bulb

205484101

Replacement Bulb

205484201

Replacement Bulb

205484001

Replacement Bulb

205484101

Replacement Bulb

205484201

Replacement Bulb

205484001

Replacement Bulb

205484101

Replacement Bulb

205484201

Replacement Bulb

205484001

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets