The Daikin Air Conditioner FTXS50KVMA is a high-efficiency split system designed for optimal cooling and comfort. With advanced features and reliable performance, this model is ideal for residential and commercial applications, ensuring energy savings and superior air quality. Experience the quality and innovation of Daikin in your space.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Air Conditioner FTXS50KVMA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Air Conditioner Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation
If no drain water is seen, is water leaking from the indoor unit?
Before a long idle period
Operate the FAN only for several hours on a nice day to dry out the inside
After operation stops, turn off the breaker for the room air conditioner
Clean the air filters and set them again
Take out batteries from the remote controller
Air Conditioner Front Panel Cleaning
CAUTION: When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
CAUTION: When removing or attaching the front panel, support the panel securely with hand to prevent it from falling
CAUTION: After cleaning, make sure that the front panel is securely fixed
Is the front panel bothered by dirt?
If the front panel is dirty, follow the steps below to clean it
Step 1: Remove the front panel
Open the front panel
Slide the front panel to either the left or right and pulling it toward you. This will disconnect the front panel shaft on one side
Disconnect the front panel shaft on the other side in the same manner
Air Conditioner Units Cleaning
CAUTION: Before cleaning, be sure to stop the operation and turn the breaker off
Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury
Is the operation stopped and breaker turned off?
Is the indoor unit, outdoor unit and remote controller clean?
For cleaning, do not use the materials as follows: Hot water above 40°C, Benzine, gasoline, thinner, other volatile oils, Polishing compound, Scrubbing brushes, other hard stuff
Were the correct cleaning materials used?
Sign off on the air conditioner units cleaning
1 Yearly Air Conditioner Batteries Replacement
Warning: Use batteries of the same type and replace the 2 old batteries together
Batteries replaced?
If the system is not used for a long time, take the batteries out
The batteries will last for approx. 1 year. If the remote controller display begins to fade and the degradation of reception performance occurs within a year, replace both 2 batteries with new, size AAA.LR03 (alkaline)
The attached batteries are provided for the initial use of the system. The usable period of the batteries may be short depending on the manufactured date of the air conditioner
Sign off on the battery replacement
6 Monthly Air Conditioner Air-Purifying Filter Maintenance
Open the front panel and pull out the air filters
Hold the recessed parts of the frame and unhook the 4 claws
Take off the titanium apatite photocatalytic air-purifying filter
Vacuum dusts from the filter
Soak in lukewarm water or water for about 10 to 15 minutes if dirt is heavy
After washing, shake off remaining water and dry in the shade
Remove the tabs on the filter frame and replace with a new filter if necessary
Set the filters as they were and close the front panel
Note any issues or difficulties encountered during the process
Access the parts list for your equipment in MaintainX.
Cooling Pump
ARC452A13
Heat Pump
ARC452A4
Air-Purifying Filter
KAF970A46
Dry Batteries
AAA.LR03
Cooling Pump
ARC452A13
Heat Pump
ARC452A4
Air-Purifying Filter
KAF970A46
Dry Batteries
AAA.LR03
Cooling Pump
ARC452A13
Heat Pump
ARC452A4
Air-Purifying Filter
KAF970A46
Dry Batteries
AAA.LR03
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX