Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Daikin Air Conditioner FTK18NMVJU
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
6 Monthly Titanium Apatite Photocatalytic Air-Purifying Fillter Cleaning
CAUTION! Before cleaning, be sure to stop the operation and turn off the circuit breaker. Do not touch the aluminium fins of the indoor unit. If you touch those parts, this may cause an injury
Did you open the front panel and pull out the air filters?
Did you take off the titanium apatite photocatalytic air-purifying filters? Hold the recessed parts of the frame and unhook the 4 claws.
Did you clean or replace the titanium apatite photocatalytic air-purifying filters? Vacuum dust, and soak in lukewarm water or water for about 10 to 15 minutes if very dirty. Do not remove the filter from the frame when washing with water.
After washing, did you shake off remaining water and let them dry in the shade? Do not wring out the filter to remove water from it.
Did you insert the titanium apatite photocatalytic air-purifying filters as they were? When attaching the filter, check that the filter is properly set in the tabs.
Did you reattach the filters?
Did you close the front panel slowly?
NOTE! For cleaning, do not use any of the following: Water hotter than 104°F (40°C), Volatile liquid such as benzene, petrol and thinner, Polishing compounds, Rough materials such as a scrubbing brush
Front Panel Cleaning
CAUTION! Before cleaning, be sure to stop the operation and turn off the circuit breaker
Do not touch the aluminium fins of the indoor unit. If you touch those parts, this may cause an injury
Did you stop the operation and turn off the circuit breaker?
Did you avoid touching the aluminium fins of the indoor unit?
Wipe it with a soft damp cloth
Only neutral detergent may be used
NOTE! For cleaning, do not use any of the following
Avoid using the following for cleaning
Sign off on the front panel cleaning
3 Yearly Titanium Apatite Photocatalytic Air-Purifying Fillter Replacement
CAUTION! Before cleaning, be sure to stop the operation and turn off the circuit breaker. Do not touch the aluminium fins of the indoor unit. If you touch those parts, this may cause an injury
Open the front panel and pull out the air filters
Take off the titanium apatite photocatalytic air-purifying filters. Hold the recessed parts of the frame and unhook the 4 claws.
Clean or replace the titanium apatite photocatalytic air-purifying filters. Remove the filter from the filter frame and prepare a new one. Dispose of the old filter as non-flammable waste
Insert the titanium apatite photocatalytic air-purifying filters as they were. When attaching the filter, check that the filter is properly set in the tabs
Reattach the filters
Close the front panel slowly
NOTE! For cleaning, do not use any of the following: Water hotter than 104°F (40°C), Volatile liquid such as benzene, petrol and thinner, Polishing compounds, Rough materials such as a scrubbing brush
NOTE! Operation with dirty filters cannot deodorize the air, cannot clean the air, results in poor cooling, may cause odor. Dispose of old filters as non-flammable waste
2 Weekly Air Filter Cleaning
CAUTION! Before cleaning, be sure to stop the operation and turn off the circuit breaker. Do not touch the aluminium fins of the indoor unit. If you touch those parts, this may cause an injury
Front panel opened
Air filters pulled out
Air filters cleaned with water or vacuum cleaner
If the dust does not come off easily, were the air filters washed with neutral detergent thinned with lukewarm water?
Titanium apatite photocatalytic air-purifying filter removed
Air filters reattached
Front panel closed securely
NOTE! For cleaning, do not use any of the following: Water hotter than 104°F (40°C), Volatile liquid such as benzene, petrol and thinner, Polishing compounds, Rough materials such as a scrubbing brush
Indoor Unit, Outdoor Unit and Remote Controller Cleaning
CAUTION! Before cleaning, be sure to stop the operation and turn off the circuit breaker
Do not touch the aluminium fins of the indoor unit. If you touch those parts, this may cause an injury
Did you wipe them with a soft cloth?
NOTE! For cleaning, do not use any of the following
Confirm you did not use any of the following for cleaning
Sign off on the cleaning procedure
Access the parts list for your equipment in MaintainX.
Titanium Apatite Photocatalytic Air-Purifying Filter without Frame
KAF970A46
Titanium Apatite Photocatalytic Air-Purifying Filter with Frame
KAF970A45
Titanium Apatite Photocatalytic Air-Purifying Filter without Frame
KAF970A46
Titanium Apatite Photocatalytic Air-Purifying Filter with Frame
KAF970A45
Titanium Apatite Photocatalytic Air-Purifying Filter without Frame
KAF970A46
Titanium Apatite Photocatalytic Air-Purifying Filter with Frame
KAF970A45
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX