MaintainX Logo
EnterprisePricing
Bunn

Bunn Brewer ITB

Need answers fast?
Explore the manual using AI.

Bunn Brewer ITB
Bunn Brewer ITB

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Bunn Brewer ITB

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Bunn Brewer ITB

Bunn Brewer ITB

Create an account to install this asset package.

Maintenance Plans for Bunn Brewer Model ITB

Integrate maintenance plans directly into your work orders in MaintainX.

1 Weekly Brewer Sprayhead Cleaning

Check mark

NOTE - Any buildup on the sprayhead may restrict water flow, and impact your brewing. For consistently great tea and coffee, clean sprayhead weekly with sprayhead cleaning tool (#38227.0000). Upon visual inspection it may appear that light passes through all holes in the sprayhead, but a thin film of residue can pass light and still impede water flow

Check mark

Remove sprayhead from brewer

Check mark

Use the pointed end of sprayhead cleaning tool to remove any mineral deposits from the sprayhead holes

Check mark

Insert the long end of sprayhead cleaning tool into the sprayhead fitting, and rotate several times to remove any mineral deposits from the fitting

Check mark

Sign off on the sprayhead cleaning

Run this procedureArrow right

Brewer Tank Maintenance

Check mark

Warning: This maintenance check requires trained personnel with PPE!

Check mark

Back access cover removed

Check mark

White shutoff clamp on the long hose closed

Check mark

Hose clamp and hose disconnected from inlet solenoid or check valve

Check mark

End of the drain hose placed in a container with minimum capacity

Check mark

White clamp released to drain water from the tank

Check mark

Hose replaced onto solenoid (or flow control) and black clamp tightened

Check mark

Note: Do not tighten white clamp!

Check mark

Access cover replaced

Run this procedureArrow right

Brewer Sweetener Cleaning

Check mark

Remove all the quick disconnects (QCD) from all the B.I.B. containers

Check mark

Fill a suitable pail or bucket with a warm soapy tap water solution. (140° F)

Check mark

Submerge all disconnects (gas and liquid) in the soapy solution and then clean them using a nylon bristle brush. (Do not use a wire brush). Rinse with clean water

Check mark

Prepare approximately five (5) gallons of Kay-5 (or equivalent) sanitizing solution with at least 100 ppm of available chlorine in 120° F water

Check mark

Rinse the B.I.B. disconnects (QCD's) in the sanitizing solution

Check mark

Attach special sanitizing fittings to each B.I.B. disconnect (QCD’s)

Check mark

Place all the B.I.B. disconnects (QCD's) into the pail of sanitizing solution

Check mark

Press and hold the left hidden switch until the display reads: 'SanitizeSweetnr?' Press 'YES'. Next screen will ask 'CONTAINER READY?'

Check mark

Press 'YES'. Allow solution to flow from dilution nozzle for a few seconds

Run this procedureArrow right

1 Daily Brewer Cleaning

Check mark

CAUTION - DO NOT KEEP BREWED ICED TEA OVERNIGHT. THE SERVER MUST BE CLEANED DAILY

Check mark

Remove and thoroughly clean the entire brew funnel. The funnel tip and screen must be free from any tea particles or residue. Reassemble the funnel

Check mark

Remove and thoroughly rinse the sprayhead. The holes must be open and clear of any mineral deposits. Wipe the sprayhead panel clean with a damp cloth

Check mark

The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. Do NOT clean this equipment with a water jet device

Check mark

Sign off on the daily brewer cleaning

Run this procedureArrow right

Parts for Bunn Brewer ITB

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Power Supply Cold

01699.0000

Sprayhead Cleaning Tool

38227.0000

Power Supply Cold

01699.0000

Sprayhead Cleaning Tool

38227.0000

Power Supply Cold

01699.0000

Sprayhead Cleaning Tool

38227.0000

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Bunn

Explore Other Assets