Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Bradford White Water Heater M4TW60T6FBN
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Burner Air Shutter Calibration
Cast Iron Burner Air Shutter Adjustment
Take necessary precautions to prevent personal injury due to hot components
Remove outer jacket door and slide inner door from left to right to open
Loosen the air shutter nut and adjust the air shutter for proper burning
Tighten the air shutter nut after adjustment
Is the flame as blue as possible with a minimum of yellow tips?
Is the burner operating quietly without lifting off the burner ports?
Close inner door and observe burner operation
Does the burner operate as adjusted with the inner door closed?
120 VAC Circuit Testing
120 VAC Circuit Trace
Verify 120VAC and proper polarity at wall outlet.
With unit plugged in and control power switch in the “ON” position, verify LED status.
LED status options
Using a volt meter set to volts AC, is there 120VAC across terminals shown in photo 29?
Is there 120VAC across terminals shown in photo 30?
Is there 120VAC across black & white wires as shown in photo 32?
Check for 120VAC between black & white wires.
Verify error code as listed on page 13.
Blower Testing
Blower Testing
Position gas control power switch to 'ON' position and adjust control to call for heat.
Remove the three screws from control access cover on blower assembly and remove cover.
Does blower energize within 2 minutes?
If blower does not energize within 2 minutes, does it run for 30 seconds and shut down?
Is there 115 VAC at wall outlet?
Check power cord for damage.
Repair or replace power cord if damaged.
Replace blower if necessary.
Pilot Inspection
Pilot Inspection, Testing and Replacement
Position gas control power switch to the “OFF” position and unplug heater from wall outlet.
Turn off gas supply to water heater.
Remove outer jacket door and slide inner door open from left to right.
Disconnect pilot tube nut (7/16 wrench) and feedline nut (¾ wrench) from gas control.
Disconnect igniter/flame sense wire from gas control.
Remove burner assembly from combustion chamber.
Remove pilot assembly from feedline (¼" nut driver).
Visually inspect igniter/flame sense wire for damage. Replace pilot if damage is found.
Pressure Switch Maintenance
Pressure Switch Replacement
Position gas control power switch to 'OFF' position
Remove the three screws from control access cover on blower assembly and remove cover
Carefully remove pressure switch from blower housing
Disconnect tubing from pressure switch
Disconnect yellow wires from pressure switch
Reconnect wires to new pressure switch
Reconnect tubing to new pressure switch
Carefully position pressure switch into blower housing
Access the parts list for your equipment in MaintainX.
Gas Control Service Tool
239-45991-00
Gas Control Service Tool
239-45991-00
Gas Control Service Tool
239-45991-00
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX