PDF MANUAL

Manual for BioTek Instruments Microplate Dispenser Multiflo

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

BioTek Instruments Microplate Dispenser Multiflo

BioTek Instruments Microplate Dispenser Multiflo

Create an account to install this asset package.

Maintenance Plans for BioTek Instruments Microplate Dispenser Model Multiflo

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Microplate Dispenser Maintenance

Check mark

Flush dispense cassette

Check mark

Record number of plates processed with cassette

Check mark

Run S-DAY_RINSE_A&B

Check mark

Run AutoPrime

Check mark

Remove protein residuals and fungi growth, (if necessary)

Check mark

Check/empty waste bottles

Check mark

Daily maintenance involves flushing the dispensers with an appropriate reagent or deionized water throughout the day. Routine rinsing helps to prevent the tubes from clogging between runs.

Check mark

Flushing the devices with deionized water is recommended at the end of the day for most applications.

Check mark

The recommended rinsing frequency depends on the solutions currently in use:

Run this procedureArrow right

1 Monthly Microplate Dispenser Maintenance

Check mark

Clean bottles

Check mark

Clean and rinse the supply bottles with deionized water before the first use, before each refill, and, periodically, as necessary, to prevent bacteria growth.

Check mark

Empty the waste bottle often (at least daily), and firmly seat the waste bottle stopper.

Check mark

Rinse the covers every time the wash or rinse bottles are filled.

Check mark

Accumulated algae, fungi, or mold may require decontamination.

Check mark

Clean dispense tubes

Check mark

Do NOT autoclave the dual 8-tube and 32-tube dispense manifolds!

Check mark

Note: The autoclavable 16-tube and non-autoclavable 8-tube manifolds have removable dispense tubes. We do not recommend routinely removing these tubes. In the case of a particularly difficult problem with any one channel, however, a tube may be removed and cleaned individually, or replaced.

Check mark

Clean the Tubes

Run this procedureArrow right

1 Weekly Microplate Dispenser Maintenance

Check mark

Clean plate carrier system

Check mark

If liquid has overflowed onto the plate carrier, transport rail, or platform, some buildup may occur and prevent the microplate from seating correctly on the carrier.

Check mark

This can interfere with plate transport. Weekly cleaning is recommended.

Check mark

1. Turn the instrument off.

Check mark

2. Loosen the thumbscrew on the left side of the carrier to release the little bracket that holds the carrier in place and remove the carrier.

Check mark

3. Clean the carrier, rails, and surface, using mild detergent and hot water, 70% isopropyl alcohol, or ethanol. Clean the priming trough, too.

Check mark

4. If detergent was used, wipe the components with a cloth moistened with water. Use a clean, dry cloth to dry the components.

Check mark

5. Reinstall the carrier:

Check mark

Clip the bottom bracket onto the transport rail, align the little bracket on the left rail to hold the carrier in place and tighten the thumbscrew.

Run this procedureArrow right

Microplate Dispenser Maintenance

Check mark

Before storage/shipment; Run S-LONG_SHUTDOWN; Recalibrate Peri-pump cassette

Check mark

Upload the PDF folder on the operator's manual CD for detailed instructions for two methods of recalibrating the cassette.

Check mark

Peri-pump dispense tips replaced

Check mark

Peri-pump cassette tubing replaced

Check mark

Syringe manifold check valves and plugs replaced

Check mark

The check valves do not twist open. If the check valves leak or become clogged, you can either clean or replace them.

Check mark

Contacted BioTek Customer Service to order replacement check valves

Check mark

To clean a check valve:

Check mark

Pulled the tubing off the check valve

Run this procedureArrow right

Overnight/Multi-Day Maintenance

Check mark

Maintaining 1536-well Hardware

Check mark

32-tube-SB dispense manifolds are not clogged

Check mark

Submerge and Shutdown

Check mark

Run S-DAY_RINSE_A&B without emptying the priming trough inserts

Check mark

Turned off the instrument?

Check mark

Lowered the manifolds into the priming trough?

Check mark

32-tube Syringe Dispenser

Check mark

Enter the volume of AutoPrime parameters

Check mark

Enter the flow rate of AutoPrime parameters

Run this procedureArrow right

Parts for BioTek Instruments Microplate Dispenser Multiflo

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

10 Cc Syringe And Tubing For Peri-Pump Cassette Maintenance

49919

10 Ul Plastic, Large Bore Tips

7172039

10 Ul Plastic, Large Bore Tips Cassette

7170024

10 Ul Plastic Tips

7172059

10 Ul Plastic Tips Cassette

7170010

10 Cc Syringe And Tubing For Peri-Pump Cassette Maintenance

49919

10 Ul Plastic, Large Bore Tips

7172039

10 Ul Plastic, Large Bore Tips Cassette

7170024

10 Ul Plastic Tips

7172059

10 Ul Plastic Tips Cassette

7170010

10 Cc Syringe And Tubing For Peri-Pump Cassette Maintenance

49919

10 Ul Plastic, Large Bore Tips

7172039

10 Ul Plastic, Large Bore Tips Cassette

7170024

10 Ul Plastic Tips

7172059

10 Ul Plastic Tips Cassette

7170010

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

Explore Other Assets