Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Atlas Copco Oil-Water Separator OSC 600
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Weekly Condensate Check
Condensate Check Procedure
Is the compressor operational?
If the compressor is not operational, report the issue to the maintenance team and stop the procedure.
Open the test valve and collect the condensate in the test bottle.
Enter the turbidity of the sample
Does the turbidity of the sample match with the 15 ppm turbidity reference bottle?
Sign off on the condensate check
Oleophilic Filter Replacement
Warning: This procedure requires trained personnel with PPE!
Service indicator approaches the lid of the housing?
Condensate from the test outlet is less transparent than in the reference test capsule?
Replacement instructions
Compressor stopped and air outlet valve closed?
Voltage switched off?
Outlet piping depressurised by opening the manual condensate drain?
Lid of the first tower removed and oleophilic filter taken out?
On OSC 355 up to OSC 1200, lid of the second tower removed and small oleophilic filter removed?
Activated Carbon Filter Replacement
Oleophilic filters changed for the second time
Filters are clogged
Service indicator is rising
Condensate from the test outlet is less transparent than in the reference glass
Replacement instructions
Compressor stopped and air outlet valve closed
Voltage switched off
Compressor depressurised by opening the manual condensate drain
Lid of the second tower removed
Access the parts list for your equipment in MaintainX.
Service Kit A
2901 1404 00
Service Kit B
2901 1404 01
Service Kit D
2901 1579 00
Alarm
8092 2849 29
Manifold
8070 2167 11
Service Kit A
2901 1404 00
Service Kit B
2901 1404 01
Service Kit D
2901 1579 00
Alarm
8092 2849 29
Manifold
8070 2167 11
Service Kit A
2901 1404 00
Service Kit B
2901 1404 01
Service Kit D
2901 1579 00
Alarm
8092 2849 29
Manifold
8070 2167 11
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX