The Atlas Copco GA55 FF is an oil-injected rotary screw compressor designed for high efficiency and reliability in industrial applications. This model offers advanced features for optimal performance, ensuring a consistent supply of compressed air while minimizing energy consumption and maintenance needs.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Atlas Copco Oil-injected rotary screw compressors GA55 FF
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Maintenance
Check that condensate is discharged when pressing the test button on top of the electronic water drain.
On compressors with integrated dryer:
• Stop the compressor, close the air outlet valve and switch off the voltage.
• Remove any dirt from the condenser inlet with a vacuum cleaner.
• Next, clean with an air jet in the reverse direction of the normal flow. Use low pressure air. Keep the compressed air nozzle more than 30 cm away from the condenser to avoid damaging the of condenser fins.
• Remove dust from inside the dryer, e.g. with a vacuum cleaner.
Do not use water or solvents to clean the condenser.;
1 Yearly Testing
Warning: Never run the compressor without safety valve
Safety valve cap unscrewed one or two turns and retightened
Compressor depressurised before removing the valve
Safety valve tested on a separate air line
Did the valve open at the set pressure stamped on the valve?
If the valve did not open at the set pressure, it needs to be replaced
Sign off on the yearly testing
8000 Hourly Maintenance
If Atlas Copco Roto-Xtend Duty Fluid is used, change oil and oil filter.
Have the oil separator element replaced.
Visually inspect the oil separator vessel for damage and corrosion. The minimum wall thickness must be respected. See section Pressure equipment directives.;
4000 Hourly Maintenance
Replace the air filter element.
Replace the filter element of the electric cabinet.
Clean coolers.
Check pressure and temperature readings.
Do a LED and a display test.
Check for leakages.
Open the manual drain valve (Dm) to clean the filter of the automatic drain. See section
Condensate system.
Test the temperature shut-down function.
1 Daily Maintenance
Check oil level.
Check readings on display.
Check air filter service indicator.
Check that condensate is discharged during operation.
Drain condensate.
On water-cooled units: check for cooling water flow.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX