MaintainX Asset Hub logo
EnterprisePricing
Atlas Copco

Atlas Copco Air Dryer FX1160

Need answers fast?
Explore the manual using AI.

Atlas Copco Air Dryer FX1160
Atlas Copco Air Dryer FX1160

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Atlas Copco Air Dryer FX1160

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Atlas Copco Air Dryer FX1160

Atlas Copco Air Dryer FX1160

Create an account to install this asset package.

Maintenance Plans for Atlas Copco Air Dryer Model FX1160

Integrate maintenance plans directly into your work orders in MaintainX.

Air Dryer Cleaning

Check mark

Safety precautions: When handling refrigerant gas, all applicable safety precautions must be observed.

Check mark

Contact of refrigerant with the skin will cause frostbite. Wear special gloves and, in case of skin contact, rinse with water. For no reason the clothes should be removed.

Check mark

Refrigerant fluid can cause also freezing of the eyes; therefore, safety glasses must be worn.

Check mark

Refrigerant is poisonous. Do not inhale refrigerant vapours. Check that the working area is adequately ventilated.

Check mark

When the dryer is filled with refrigerant, it is forbidden to remove the refrigerant compressor inlet sensor.

Check mark

When removing the side panels of the dryer, be aware that internal elements such as the pipes can reach a temperature of 120˚C (248˚F). Therefore, wait until the dryer has cooled down before removing the side panels.

Check mark

Before starting any maintenance or repairs, switch off the voltage. Isolate the dryer from the air net and depressurize the unit following the pressure discharge procedure.

Check mark

Keep the dryer clean.

Check mark

Brush or blow off the finned surface of the condenser regularly.

Run this procedureArrow right

1 Yearly Electronic Water Drain Cleaning

Check mark

Safety precautions

Check mark

When handling refrigerant gas, all applicable safety precautions must be observed. The following points are stressed:

Check mark

Safety measures

Check mark

The condensate drain filter must be cleaned.

Check mark

Proceed as follows:

Check mark

Close the inlet and outlet valves (1)

Check mark

Remove the panel (2) and depressurize the dryer by pressing and holding down the “TEST” button located on the top of the drain (3)

Check mark

Switch off the machine (pushing the “OFF” button) (4)

Check mark

Disconnect the power supply (5)

Run this procedureArrow right

4000 Hourly/2 Yearly Wear Kit Drain Replacement

Check mark

Safety precautions: When handling refrigerant gas, all applicable safety precautions must be observed.

Check mark

Contact of refrigerant with the skin will cause frostbite. Wear special gloves and, in case of skin contact, rinse with water. For no reason the clothes should be removed.

Check mark

Refrigerant fluid can cause also freezing of the eyes; therefore, safety glasses must be worn.

Check mark

Refrigerant is poisonous. Do not inhale refrigerant vapours. Check that the working area is adequately ventilated.

Check mark

When the dryer is filled with refrigerant, it is forbidden to remove the refrigerant compressor inlet sensor.

Check mark

When removing the side panels of the dryer, be aware that internal elements such as the pipes can reach a temperature of 120˚C (248˚F). Therefore, wait until the dryer has cooled down before removing the side panels.

Check mark

Before starting any maintenance or repairs, switch off the voltage. Isolate the dryer from the air net and depressurize the unit following the pressure discharge procedure.

Check mark

Wear kit drain (2200902017) replaced?

Run this procedureArrow right

2000 Hourly/1 Yearly Drain Filter Replacement

Check mark

Safety precautions: When handling refrigerant gas, all applicable safety precautions must be observed.

Check mark

Contact of refrigerant with the skin will cause frostbite. Wear special gloves and, in case of skin contact, rinse with water. For no reason the clothes should be removed.

Check mark

Refrigerant fluid can cause also freezing of the eyes; therefore, safety glasses must be worn.

Check mark

Refrigerant is poisonous. Do not inhale refrigerant vapours. Check that the working area is adequately ventilated.

Check mark

When the dryer is filled with refrigerant, it is forbidden to remove the refrigerant compressor inlet sensor.

Check mark

When removing the side panels of the dryer, be aware that internal elements such as the pipes can reach a temperature of 120˚C (248˚F). Therefore, wait until the dryer has cooled down before removing the side panels.

Check mark

Before starting any maintenance or repairs, switch off the voltage. Isolate the dryer from the air net and depressurize the unit following the pressure discharge procedure.

Check mark

Drain filter (0803501008) replaced

Check mark

Sign off on the drain filter replacement

Run this procedureArrow right

1 Weekly Air Dryer Cleaning

Check mark

Safety precautions: When handling refrigerant gas, all applicable safety precautions must be observed.

Check mark

Contact of refrigerant with the skin will cause frostbite. Wear special gloves and, in case of skin contact, rinse with water. For no reason the clothes should be removed.

Check mark

Refrigerant fluid can cause also freezing of the eyes; therefore, safety glasses must be worn.

Check mark

Refrigerant is poisonous. Do not inhale refrigerant vapours. Check that the working area is adequately ventilated.

Check mark

When the dryer is filled with refrigerant, it is forbidden to remove the refrigerant compressor inlet sensor.

Check mark

When removing the side panels of the dryer, be aware that internal elements such as the pipes can reach a temperature of 120˚C (248˚F). Therefore, wait until the dryer has cooled down before removing the side panels.

Check mark

Before starting any maintenance or repairs, switch off the voltage. Isolate the dryer from the air net and depressurize the unit following the pressure discharge procedure.

Check mark

Clean the condenser surface with an air flow from the inside towards the outside

Check mark

Clean drain filter

Run this procedureArrow right

Parts for Atlas Copco Air Dryer FX1160

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Drain Filter

803501008

Wear Kit Drain

2200902017

Drain Filter

803501008

Wear Kit Drain

2200902017

Drain Filter

803501008

Wear Kit Drain

2200902017

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Atlas Copco

Explore Other Assets