The Atlas Copco Oil-Sealed Rotary Screw Vacuum Pump GHS 730 VSD+ is a high-performance vacuum pump designed for industrial applications. With its variable speed drive technology, it optimizes energy consumption while delivering reliable vacuum performance, making it an ideal choice for various manufacturing processes.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Atlas Copco Oil-Sealed Rotary Screw Vacuum Pump GHS 730 VSD+
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
24000 Hourly Pump Maintenance
Motor overhaul
Change lipseal assembly
Replacement of tubes
Select the condition of the element
Element overhaul in Normal condition every 48000 Hours, in Medium condition every 36000 Hours and in Harsh condition every 24000 Hours
Sign off on the pump maintenance
4000 Hourly / 1 Yearly Pump Maintenance
Change oil. In medium and harsh applications an optional 500 hrs oil sample is recommended. In Medium condition interval should be 2000 Hours while in Harsh condition interval should be 1000 Hours
Change oil filter. In Medium condition interval should be 2000 Hours while in Harsh condition interval should be 1000 Hours
Replace the air filter elements. In Medium condition interval should be 2000 Hours while in Harsh condition interval should be 1000 Hours
Clean the scavange line and blow out the restriction nozzle. In Medium condition interval should be 2000 Hours while in Harsh condition interval should be 1000 Hours
Replace the oil seperator elements. In Medium condition interval should be 4000 Hours while in Harsh condition interval should be 2000 Hours
Check pressure and temperature readings. In Medium condition interval should be 4000 Hours while in Harsh condition interval should be 2000 Hours
Check operation of cooling fans of converter and clean heatsink. In Medium condition interval should be 4000 Hours while in Harsh condition interval should be 2000 Hours
Check vacuum control valve solenoid and gasballast solenoid valve. In Medium condition interval should be 4000 Hours while in Harsh condition interval should be 2000 Hours
Clean coolers. In Medium condition interval should be 4000 Hours while in Harsh condition interval should be 2000 Hours
1 Daily Pump Check
Check oil level
Check oil condition
Check readings on display
Sign off on the daily pump check
3 Monthly Pump Check
Check coolers, clean if necessary
Check the filter elements of the electric cabinet. Replace if necessary
Check the silencer of the vacuum control valve, clean if necessary
1 Monthly Pump Maintenance
Remove the air filter elements
Inspect the air filter elements
Are there any damaged or heavily contaminated elements?
Replace damaged or heavily contaminated elements
Check for possible air leakages
Check for possible oil leakages
Sign off on the pump maintenance
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX