The AO Smith Commercial Gas Tank Water Heater BL-80 is a reliable and efficient solution for high-demand hot water needs. Designed for commercial applications, this model ensures optimal performance and longevity, making it an ideal choice for businesses seeking dependable hot water solutions.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

A.O. Smith Commercial Gas Tank Water Heaters BL-80
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Tank Cleanout Procedure
Flush the heater by opening the drain valve and allowing two gallons of water to drain. Keep the inlet water valve open to maintain pressure in the tank.
Shut off the gas and drain the heater before opening the cleanout.
Drain the heater.
Remove the outer cover plate from the lower side of the heater jacket.
Remove the six hex head screws securing the tank cleanout plate and remove the plate.
Remove lime, scale, or sediment, taking care not to damage the glass lining.
Inspect the cleanout plate gasket. If a new gasket is required, refer to the replacement parts list for the item number.
Install the cleanout plate. Ensure the plate is drawn up tight by securely tightening the screws.
Replace the outer jacket cover plate.
1 Yearly Anode Rod Inspection
CAUTION! Property Damage Hazard. Avoid water heater damage. Inspection and replacement of anode rod required.
The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank.
Anode deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact.
Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions. The use of a water softener may decrease the life of the water heater tank.
The anode rod should be inspected after a maximum of three years and annually thereafter until the condition of the anode rod dictates its replacement.
NOTE: Artificially softened water requires the anode rod to be inspected annually.
The following are typical (but not all) signs of a depleted anode rod: The majority of the rods diameter is less than 3/8. Significant sections of the support wire (approx. 1/3 or more of the anode rod's length) are visible.
Anode rod in good condition?
Enter the diameter of the anode rod
1 Yearly Burner Maintenance
Warning: Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a flooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
Contact a qualified installer or service technician to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!
Visual inspection of the main burner and pilot burner
Inspect burner flames through viewport. Flames should be very small with a blue haze and small amounts of yellow or orange at the edges. After several minutes of operation the burner screen may glow red.
Check for sooting. Soot is not normal and will impair proper combustion.
Soot build-up indicates a problem that requires correction before further use. Turn 'OFF' gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fire causing death, serious injury, or property damage.
BURNER CLEANING
If inspection of the burner shows that cleaning is required, turn the gas control knob clockwise ( ) to the “OFF” position, depressing slightly.
NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly. DO NOT FORCE.
1 Yearly Venting System Inspection
WARNING! Carbon Monoxide and Fire Hazard
Flue gases may escape if vent pipe is not connected.
Be alert for obstructed, sooted or deteriorated vent system to avoid serious injury or death.
Do not store corrosive chemicals in vicinity of water heater.
Chemical corrosion of flue and vent system can cause serious injury or death.
Contact a qualified installer or service agency.
Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual.
Visual inspection of the venting system done
Obstructions which could cause improper venting found
6 Monthly Temperature-Pressure Relief Valve Test
DANGER: Burn hazard. Hot water discharge. Keep clear of Temperature-Pressure Relief Valve discharge outlet.
It is recommended that the Temperature-Pressure Relief Valve should be checked to ensure that it is in operating condition every 6 months.
When checking the Temperature-Pressure Relief Valve operation, make sure that no one is in front of or around the outlet of the Temperature-Pressure Relief Valve discharge line, and that the water discharge will not cause any property damage, as water may be extremely hot.
Use care when operating valve as the valve may be hot.
To check the temperature-pressure relief valve, lift the lever at the end of the valve several times. The valve should seat properly and operate freely.
If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater and drain the water heater.
Replace the Temperature- Pressure Relief Valve with a properly rated/sized new one.
If the Temperature-Pressure Relief Valve on the water heater weeps or discharges periodically, this may be due to thermal expansion.
NOTE: Excessive water pressure is the most common cause of Temperature-Pressure Relief Valve leakage. Excessive water system pressure is most often caused by “thermal expansion” in a “closed system.”
Access the parts list for your equipment in MaintainX.
Anode Rod
9003892005
Burner Door Assembly
9009071005
Burner Manifold w/Orifice
9009070005
Cleanout Cover
9005797205
Cleanout Gasket
9004099215
Anode Rod
9003892005
Burner Door Assembly
9009071005
Burner Manifold w/Orifice
9009070005
Cleanout Cover
9005797205
Cleanout Gasket
9004099215
Anode Rod
9003892005
Burner Door Assembly
9009071005
Burner Manifold w/Orifice
9009070005
Cleanout Cover
9005797205
Cleanout Gasket
9004099215
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX