Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Airedale International Air Conditioning Free-Cooling Chiller UCFC330DQ-12/2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
12 Monthly Chiller Maintenance
Safety Precautions
Ensure all work is carried out by technically trained competent personnel
Isolate equipment to ensure no live electrical or moving parts are active
6 Month Checks
Repeat 6 month checks
12 Month Specific Checks
Check safety devices cut out the compressor at the correct settings
Tighten all electrical terminals
3 Monthly Chiller System Check
Safety Precautions
Ensure all work is carried out by technically trained competent personnel
Isolate equipment to ensure no live electrical or moving parts are accessible
Commissioning Records Verification
Verify the following against commissioning records
Chilled Water System Check
Ensure chilled water pump and flow switch operate efficiently
Verify interlocks function correctly
Check operation of waterflow switch and pump interlock
6 Monthly Chiller Maintenance
Safety Precautions
Ensure all work is carried out by technically trained competent personnel
Isolate equipment to ensure no live electrical or moving parts are active
3 Month Checks
Complete all 3 month checks
Evaporator and Thermostat Check
Check evaporator trace heating activation temperature
Is the low ambient thermostat set to activate at 4.0°C?
Post Maintenance
12 Monthly Refrigeration System Maintenance
CAUTION!
Pre-Maintenance Safety Check
Ensure all electrical and moving parts are isolated before starting maintenance.
System Checks
Check glycol concentration if appropriate.
Leak test all R407C joints and inspect all water connections.
Check superheats with chiller running on full load (the height of summer is recommended).
Recheck the charge following major adjustment of the superheats.
Notes
3 Monthly Chiller Maintenance
CAUTION!
Visual Inspection
Inspect the unit for general wear and tear, treat metalwork.
Inspect pipe and pipework insulation.
Cleaning Tasks
Clean evaporator water strainer.
Clean condenser coils using detergent and stiff bristled brush. Avoid steam cleaning.
Visual Checks
Check the following components visually
Access the parts list for your equipment in MaintainX.
Water Flange Connections: UCFC275-450
DN100 PN16
Water Flange Connections: UCFC275-450
DN100 PN16
Water Flange Connections: UCFC275-450
DN100 PN16
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX