MaintainX Asset Hub logo
EnterprisePricing
Actron Engineering

Actron Engineering Indoor Unit EVY620T-6Q2

Need answers fast?
Explore the manual using AI.

Actron Engineering Indoor Unit EVY620T-6Q2
Actron Engineering Indoor Unit EVY620T-6Q2

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Actron Engineering Indoor Unit EVY620T-6Q2

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Actron Engineering Indoor Unit EVY620T-6Q2

Actron Engineering Indoor Unit EVY620T-6Q2

Create an account to install this asset package.

Maintenance Plans for Actron Engineering Indoor Unit Model EVY620T-6Q2

Integrate maintenance plans directly into your work orders in MaintainX.

3 Monthly Indoor Unit Preventive Maintenance

Check mark

Casing / Panels and Frames

Check mark

Visual check for damage, rust and dust accumulation

Check mark

For highly corrosive environment, wash panels quarterly with water & neutral detergent solution

Check mark

Wax panels

Check mark

Repair / re-paint where required

Check mark

Drain Pan / Condensation Line

Check mark

Check for obstructions & free flow of water

Check mark

Clean to eliminate obstructions/sludge & check condition of pan

Check mark

Pour water to ensure flow

Run this procedureArrow right

2 Yearly Indoor Unit Preventive Maintenance

Check mark

Casing / Panels and Frames

Check mark

Perform visual check for the following issues

Check mark

Is the environment highly corrosive?

Check mark

Wash panels with water & neutral detergent solution if environment is highly corrosive

Check mark

Wax panels

Check mark

Describe any repairs or repainting needed

Check mark

Insulation

Check mark

Perform visual check for insulation conditions

Check mark

Describe any repairs or replacements needed for insulation material

Run this procedureArrow right

1 Yearly Condenser Coil Cleaning

Check mark

Safety Precautions

Check mark

Ensure all power supply to the Outdoor Fans is turned off and isolated.

Check mark

Wear PPE during the maintenance procedure.

Check mark

Avoid wearing loose clothing and jewelry near the fans.

Check mark

Ensure electrical components do not get wet during cleaning.

Check mark

Coil Cleaning Procedures

Check mark

Disconnect power to the unit.

Check mark

Remove the louvered panels from the unit to access the air inlet side of the coils.

Check mark

Open evaporator access door and remove access panel to the condenser section.

Run this procedureArrow right

6 Monthly Indoor Unit Preventive Maintenance

Check mark

Fan Maintenance

Check mark

Visual check for fan run out of balance and dust attached

Check mark

Clean off dust from fan to negate possibility of running out of balance

Check mark

Heat Exchanger Maintenance

Check mark

Check heat exchanger for clogging by dust

Check mark

Check heat exchanger for leaks or damage

Check mark

Clean air inlet side of heat exchanger as necessary

Check mark

Straighten any bent fins using fins comb

Check mark

Damper Motors Maintenance (If Fitted)

Run this procedureArrow right

1 Yearly Motor Check

Check mark

Motor Inspection

Check mark

Perform visual check on wiring

Check mark

Measure insulation resistance to earth with Megger

Check mark

Is the insulation resistance more than 1MΩ?

Run this procedureArrow right

Parts for Actron Engineering Indoor Unit EVY620T-6Q2

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Compressor #1 (Small Compressor)

1560-471

Compressor #2 (Large Compressor)

1560-450

Outdoor Fan

2505-134

Thermostatic Expansion Valve

4570-128

Thermostatic Expansion Valve

4570-132

Compressor #1 (Small Compressor)

1560-471

Compressor #2 (Large Compressor)

1560-450

Outdoor Fan

2505-134

Thermostatic Expansion Valve

4570-128

Thermostatic Expansion Valve

4570-132

Compressor #1 (Small Compressor)

1560-471

Compressor #2 (Large Compressor)

1560-450

Outdoor Fan

2505-134

Thermostatic Expansion Valve

4570-128

Thermostatic Expansion Valve

4570-132

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Actron Engineering

Explore Other Assets