MaintainX Asset Hub logo
EnterprisePricing
Zhejiang Ligao Pump Technology

Zhejiang Ligao Pump Technology Metering Pump JLM1501

Need answers fast?
Explore the manual using AI.

Zhejiang Ligao Pump Technology Metering Pump JLM1501
Zhejiang Ligao Pump Technology Metering Pump JLM1501

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Zhejiang Ligao Pump Technology Metering Pump JLM1501

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Zhejiang Ligao Pump Technology Metering Pump JLM1501

Zhejiang Ligao Pump Technology Metering Pump JLM1501

Create an account to install this asset package.

Maintenance Plans for Zhejiang Ligao Pump Technology Metering Pump Model JLM1501

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Check Valves Replacement

Check mark

Safety Precautions

Check mark

Ensure electrical maintenance is carried out by qualified electricians.

Check mark

Unplug the power plug or disconnect the power.

Check mark

Cut off power if there is a relay.

Check mark

Ensure the pump's power supply is not turned on during maintenance.

Check mark

Ensure the drainage pipe is decompressed before maintenance.

Check mark

Discharge and wash the pump head cavity.

Check mark

Confirm no use of corrosive liquid.

Check mark

Check performance parameters of the metered liquid if it is hazardous or unknown.

Run this procedureArrow right

Metering Pump Calibration

Check mark

Pre-calibration Setup

Check mark

Ensure all components are in place

Check mark

Place the foot valve in a graduated container with a volume of 1000ml or more

Check mark

Start the pump to exhaust all air from the suction line and head

Check mark

Stop the pump and refill the graduated container to a starting level

Check mark

Calibration Process

Check mark

Record the time the pump is turned on

Check mark

Enter the number of strokes (minimum 120)

Check mark

Stop the pump after the measured time

Run this procedureArrow right

Metering Pump Maintenance

Check mark

Safety Precautions

Check mark

Ensure electrical maintenance is carried out by qualified electricians

Check mark

Unplug the power plug or disconnect the power

Check mark

Verify the pump's power supply is off during maintenance

Check mark

Preparation

Check mark

Decompress the drainage pipe before maintenance

Check mark

Discharge and wash the pump head cavity

Check mark

Ensure no corrosive liquid is used

Check mark

Check performance parameters of the metered liquid if hazardous or unknown

Run this procedureArrow right

1 Yearly Diaphragm Replacement

Check mark

Safety Precautions

Check mark

Ensure electrical maintenance is carried out by qualified electricians.

Check mark

Unplug the power plug or disconnect the power.

Check mark

Ensure the pump's power supply is not turned on during maintenance.

Check mark

Decompress the drainage pipe before maintenance.

Check mark

Discharge and wash the pump head cavity.

Check mark

Ensure no corrosive liquid is used.

Check mark

Wear protective gear

Check mark

Preparation

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Zhejiang Ligao Pump Technology

Explore Other Assets