MaintainX Asset Hub logo
EnterprisePricing
Xylem

Xylem Pump 10SV4CA1A10

Need answers fast?
Explore the manual using AI.

Xylem Pump 10SV4CA1A10
Xylem Pump 10SV4CA1A10

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Xylem Pump 10SV4CA1A10

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Xylem Pump 10SV4CA1A10

Xylem Pump 10SV4CA1A10

Create an account to install this asset package.

Maintenance Plans for Xylem Pump Model 10SV4CA1A10

Integrate maintenance plans directly into your work orders in MaintainX.

Freeze Protection Maintenance

Check mark

Operation

Check mark

Ensure the pump is inactive before draining

Check mark

Drain the pump through the drain plugs if no antifreeze is present

Check mark

Has a suitable antifreeze been added to the water?

Check mark

Describe any precautions taken to prevent damage or injuries from the drained liquid

Run this procedureArrow right

Motor Maintenance

Check mark

Motor Replacement

Check mark

Remove the motor following steps 1 through 4 in the Mechanical Seal Replacement section

Check mark

For motor frames 213TC and larger, remove the motor hex cap screws and motor adapter

Check mark

Install the motor adapter flange onto the new motor

Check mark

Torque the 4 hex cap screws to the specified values in the Engineering Data section

Check mark

Complete the reassembly following steps 17 through 22 in the Mechanical Seal Replacement section

Check mark

Note any additional unit service or maintenance required

Check mark

Contact local dealer or Goulds Water Technology distributor for assistance if needed

Run this procedureArrow right

1 Yearly Motor Bearing Lubrication

Check mark

Motor Lubrication

Check mark

Check motor operating conditions

Check mark

Is the motor operating at elevated temperatures?

Check mark

Increase lubrication frequency if operating at elevated temperatures

Check mark

Ensure not to intermix grease bases (lithium, sodium, etc.)

Check mark

Completely purge old grease if changing grease base

Check mark

Avoid over greasing to prevent excessive bearing temperatures and failures

Run this procedureArrow right

Mechanical Seal Maintenance

Check mark

Maintenance

Check mark

WARNING — DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE ATTEMPTING ANY MAINTENANCE. FAILURE TO DO SO CAN CAUSE SHOCK, BURNS OR DEATH.

Check mark

Mechanical Seal Replacement (e-SV 1–125) — Conventional Seal

Check mark

Close all necessary suction and discharge valves to isolate the pump from the system.

Check mark

Drain the liquid from the pump by removing the drain plug and opening the needle valve on the vent plug.

Check mark

Remove the coupling guards, the 4 coupling hex cap screws, the coupling and coupling drive pin.

Check mark

Remove the 4 motor hex cap screws (inner screws) on the seal housing.

Check mark

Remove the seal housing plate on 33-125SV models using the two tapped holes provided.

Check mark

Turn the seal housing upside down and remove the stationary seat and o-ring. Inspect and clean the seal seat.

Run this procedureArrow right

3 Monthly Pump Storage Maintenance

Check mark

Storing the Packed Product

Check mark

Ensure the following storage conditions are met

Check mark

Rotate shaft several times

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Xylem

Explore Other Assets