MaintainX Asset Hub logo
EnterprisePricing
Welch Allyn

Welch Allyn Ear Thermometer (Medical) Pro 6000

Need answers fast?
Explore the manual using AI.

Welch Allyn Ear Thermometer (Medical) Pro 6000
Welch Allyn Ear Thermometer (Medical) Pro 6000

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Welch Allyn Ear Thermometer (Medical) Pro 6000

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Welch Allyn Ear Thermometer (Medical) Pro 6000

Welch Allyn Ear Thermometer (Medical) Pro 6000

Create an account to install this asset package.

Maintenance Plans for Welch Allyn Ear Thermometer (Medical) Model Pro 6000

Integrate maintenance plans directly into your work orders in MaintainX.

Probe Lens Window / Probe Cleaning

Check mark

Warnings and Cautions

Check mark

Use only Hillrom Thermometer disposable probe covers.

Check mark

Do not use damaged, perforated, soiled or poor fitting probe covers. Do not reuse probe covers.

Check mark

Avoid touching probe lens window except when cleaning.

Check mark

Do not modify, change or adjust probe lens window.

Check mark

Do not use a cleaning solution other than isopropyl or ethyl alcohol.

Check mark

Cleaning Procedure

Check mark

Remove probe cover and discard.

Check mark

Moisten cotton swab or cloth slightly with isopropyl or ethyl alcohol. Do not saturate.

Run this procedureArrow right

Contact Cleaning

Check mark

CAUTION: Do not use bleach solutions of any kind when cleaning metal electrical contacts. It will damage the device.

Check mark

Cleaning Procedure

Check mark

Slightly dampen a cotton swab with 70% isopropyl alcohol.

Check mark

Remove the thermometer from the dock and clean the metal electrical contacts on the thermometer.

Check mark

Place the thermometer aside for 1 minute, allowing the contacts to air dry.

Check mark

Contingency Cleaning

Check mark

Did any cleaning agent other than isopropyl or ethyl alcohol come into contact with the probe, probe lens window, or contacts?

Check mark

If yes, immediately wipe dry and clean the probe, probe lens window, and contacts with isopropyl or ethyl alcohol.

Run this procedureArrow right

Probe Cover Box Carrier Removal

Check mark

Thermometer Removal

Check mark

Grip thermometer at base and pivot up to remove from cradle

Check mark

Probe Cover Box Carrier Removal

Check mark

Rotate the probe cover box carrier forward to remove from cradle

Check mark

Reinstallation of Probe Cover Box Carrier

Check mark

Line up the brackets of the probe cover box carrier

Check mark

Push down to place probe cover box carrier back in cradle

Run this procedureArrow right

Battery Replacement

Check mark

Battery Removal and Replacement

Check mark

Insert new batteries when the battery symbol begins to flash on the display

Check mark

Open battery door by sliding spring latch to the right using your finger or a pointed object such as a pen

Check mark

While holding the latch in the open position, grasp the battery door and remove it

Check mark

Remove the batteries and replace with new batteries, making sure the poles are in the right direction

Check mark

Snap battery door back into place and ensure the latch returns to original latch position

Check mark

Environmental Considerations

Check mark

Do not dispose of batteries in the trash

Check mark

Take batteries to appropriate local collection points according to national or local regulations

Run this procedureArrow right

Thermometer Body / Cradle Cleaning

Check mark

Preparation

Check mark

Place a new probe cover on the thermometer probe for protection during cleaning.

Check mark

Cleaning the Thermometer Body

Check mark

Use a damp cloth or cleaning wipe with approved cleaning solution.

Check mark

Ensure the wipe is moist, not saturated.

Check mark

Wipe the thermometer body with the display facing up.

Check mark

Cleaning the Cradle and Probe Cover Carrier

Check mark

Remove probe cover box carrier from the cradle by rotating it forward.

Check mark

Wipe the cradle and probe cover carrier with a damp cloth or cleaning wipe with approved cleaning solution.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Welch Allyn

Explore Other Assets