MaintainX Asset Hub logo
EnterprisePricing
WEG

WEG Frequency Inverter CFW110312T4

Need answers fast?
Explore the manual using AI.

WEG Frequency Inverter CFW110312T4
WEG Frequency Inverter CFW110312T4

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for WEG Frequency Inverter CFW110312T4

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

WEG Frequency Inverter CFW110312T4

WEG Frequency Inverter CFW110312T4

Create an account to install this asset package.

Maintenance Plans for WEG Frequency Inverter Model CFW110312T4

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Inverter Inspection

Check mark

Warning: This inspection requires trained personnel with PPE!

Check mark

Manufacturing date of the inverter

Check mark

If the inverter is stocked (not being used): Reforming

Check mark

Enter the power applied to the inverter (voltage between 220 and 230 Vac, single-phase or three-phase, 50 or 60 Hz)

Check mark

Apply power to the inverter for at least one hour

Check mark

Then, disconnect the power supply and wait at least 24 hours before using the inverter (reapply power)

Check mark

Sign off on the inverter inspection

Run this procedureArrow right

10 Yearly Electrolytic Capacitors Replacement

Check mark

- If the inverter is stocked (not being used) make electrolytic capacitors “Reforming”

Check mark

Every year from the manufacturing date printed on the inverter identification label (refer to section 2.4).

Check mark

Apply power to the inverter (voltage between 220 and 230 Vac, single-phase or three-phase, 50 or 60 Hz) for at least one hour.

Check mark

Then disconnect the power supply and wait at least 24 hours before using the inverter again (reapply power).

Check mark

- If inverter in operation replace electrolytic capacitors every 10 years.

Check mark

Contact WEG technical support to obtain the replacement procedures.;

Run this procedureArrow right

10 Yearly Keypad Battery Replacement

Check mark

Warning: Follow the steps carefully to avoid damaging the keypad

Check mark

Locate the battery access cover

Check mark

Press the cover and rotate it counterclockwise

Check mark

Remove the cover

Check mark

Remove the battery with the help of a screwdriver positioned at the right side

Check mark

Upload a photo of the HMI without the battery

Check mark

Install the new battery positioning it first at the left side

Check mark

Press the battery for its insertion

Check mark

Put the cover back and rotate it clockwise

Run this procedureArrow right

Inverter Cleaning

Check mark

When it is necessary to clean the inverter, follow the instructions below.

Check mark

Ventilation system:

Check mark

Disconnect the inverter power supply and wait at least 10 minutes.

Check mark

Remove the dust from the cooling air inlet using a soft brush or a flannel.

Check mark

Remove the dust from the heatsink fins and from the fan blades using compressed air.

Check mark

Electronic boards:

Check mark

Disconnect the inverter power supply and wait at least 10 minutes.

Check mark

Remove the dust from the electronic board using an anti-static brush or an ion air gun (Charges Burtes Ion Gun – reference A6030-6 DESCO).

Check mark

If necessary, remove the boards from the inverter.

Run this procedureArrow right

Parts for WEG Frequency Inverter CFW110312T4

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

IOA Module: 1 Voltage/Current Analog Input (14 Bits); 2 Digital Inputs; 2 Voltage/Current Analog Outputs (14 Bits); 2 Open-Collector Digital Outputs

11008162

IOB Module: 2 Isolated Analog Inputs (Voltage/Current); 2 Digital Inputs; 2 Isolated Analog Outputs (Voltage/Current); 2 Open-Collector Digital Outputs

11008099

Encoder Module: 5 To 12 Vdc Incremental Encoder Module, 100 KHz, With An Encoder Signal Repeater

11008100

Encoder Module: 5 To 12 Vdc Incremental Encoder Module, 100 KHz

11008101

RS-485 Serial Communication Module (Modbus)

11008102

IOA Module: 1 Voltage/Current Analog Input (14 Bits); 2 Digital Inputs; 2 Voltage/Current Analog Outputs (14 Bits); 2 Open-Collector Digital Outputs

11008162

IOB Module: 2 Isolated Analog Inputs (Voltage/Current); 2 Digital Inputs; 2 Isolated Analog Outputs (Voltage/Current); 2 Open-Collector Digital Outputs

11008099

Encoder Module: 5 To 12 Vdc Incremental Encoder Module, 100 KHz, With An Encoder Signal Repeater

11008100

Encoder Module: 5 To 12 Vdc Incremental Encoder Module, 100 KHz

11008101

RS-485 Serial Communication Module (Modbus)

11008102

IOA Module: 1 Voltage/Current Analog Input (14 Bits); 2 Digital Inputs; 2 Voltage/Current Analog Outputs (14 Bits); 2 Open-Collector Digital Outputs

11008162

IOB Module: 2 Isolated Analog Inputs (Voltage/Current); 2 Digital Inputs; 2 Isolated Analog Outputs (Voltage/Current); 2 Open-Collector Digital Outputs

11008099

Encoder Module: 5 To 12 Vdc Incremental Encoder Module, 100 KHz, With An Encoder Signal Repeater

11008100

Encoder Module: 5 To 12 Vdc Incremental Encoder Module, 100 KHz

11008101

RS-485 Serial Communication Module (Modbus)

11008102

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from WEG

Explore Other Assets