MaintainX Asset Hub logo
EnterprisePricing
Victory Refrigeration

Victory Refrigeration V-Series Reach-In Refrigerator VF-2

Need answers fast?
Explore the manual using AI.

Victory Refrigeration V-Series Reach-In Refrigerator VF-2
Victory Refrigeration V-Series Reach-In Refrigerator VF-2

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Victory Refrigeration V-Series Reach-In Refrigerator VF-2

Victory Refrigeration V-Series Reach-In Refrigerator VF-2

Create an account to install this asset package.

Maintenance Plans for Victory Refrigeration V-Series Reach-In Refrigerator Model VF-2

Integrate maintenance plans directly into your work orders in MaintainX.

1 Weekly Interior Cleaning

Check mark

Preparation

Check mark

Remove all items

Check mark

Turn the unit off

Check mark

Cleaning Process

Check mark

Remove loose food particles from interior floors, walls and ceiling

Check mark

Scrub all interior surfaces with warm detergent solution 100°F - 120°F (38°C - 39°C) and a nylon bristled brush

Check mark

Rinse with clear water and allow to air dry

Check mark

Reinstallation and Power Restoration

Check mark

Reinstall shelves

Run this procedureArrow right

3 Monthly Condenser Maintenance

Check mark

Preparation

Check mark

Disconnect power by switching circuit breaker to 'OFF' position.

Check mark

Remove the front grill by removing the two screws on the inside of the grill at each end, then lift the panel up and straight out.

Check mark

Cleaning

Check mark

Use a vacuum cleaner with proper brush attachments to clean the condenser, motor-compressor and related parts.

Check mark

Is there extreme dust and grease buildup?

Check mark

Extreme Cleaning

Check mark

Blow out condenser fins with compressed air.

Check mark

Clean condenser fins with a degreasing agent.

Run this procedureArrow right

Door Gasket Replacement

Check mark

Preparation

Check mark

Ensure the gasket and door are at room temperature

Check mark

Soak the gasket in warm water if necessary to make it more pliable

Check mark

Gasket Installation

Check mark

Align new gasket frame on the door retainer strip

Check mark

Press each corner of the gasket into the retainer strip

Check mark

Press roll the gasket into place around the entire perimeter of the door

Run this procedureArrow right

Dial Thermometer Adjustment

Check mark

Temperature Verification

Check mark

Record the cabinet temperature using a hand held dial or digital thermometer

Check mark

Does the cabinet grill thermometer match the test thermometer within ±1°F?

Check mark

Adjustment Procedure

Check mark

Remove the dial thermometer lens with a small screwdriver

Check mark

Insert a small screwdriver in the slotted screw on the needle

Check mark

Describe the adjustment made to the temperature needle

Check mark

Release the needle and remove the screwdriver

Check mark

Post-Adjustment Verification

Run this procedureArrow right

1 Daily Exterior Cleaning

Check mark

Surface Cleaning

Check mark

Clean surface with a sponge and cleaning solution

Check mark

Ensure non-abrasive cleaner without chlorine is used

Check mark

Polishing

Check mark

Polish with a soft cloth

Check mark

Wipe with the grain of the metal

Check mark

Weekly Maintenance

Check mark

Wipe with a film cutting agent to maintain shine

Run this procedureArrow right

Parts for Victory Refrigeration V-Series Reach-In Refrigerator VF-2

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Door Hinge Assembly

10685101

Hinge Barrel

50520102

Hinge Cover

50520105

Hinge Base

50520103

Hinge Cam

50520106

Door Hinge Assembly

10685101

Hinge Barrel

50520102

Hinge Cover

50520105

Hinge Base

50520103

Hinge Cam

50520106

Door Hinge Assembly

10685101

Hinge Barrel

50520102

Hinge Cover

50520105

Hinge Base

50520103

Hinge Cam

50520106

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Victory Refrigeration

Explore Other Assets