Trane Series R™ Helical Rotary Chiller RTHCE3D2E2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Weekly Series R™ Helical Rotary Chiller Maintenance
After the unit has operated for approximately 30 minutes and the system has stabilized, check the operating conditions and complete the procedures below:
Log the chiller.
Check evaporator and condenser pressures with gauges and compare to the reading on the Clear Language Display.
Pressure readings should fall within the following ranges specified in the Operating Conditions table:
NOTE: Optimum condenser pressure is dependent on condenser water temperature, and should equal the saturation pressure of the refrigerant at a temperature 2 to 5°F above that of leaving condenser water at full load.
Sign off on the weekly maintenance of the Series R™ Helical Rotary Chiller.
Oil Sump Level Check
Run the unit fully loaded for approximately 20 minutes.
Cycle the compressor off line.
Attach the 3/8” or 1/2” hose with a sightglass in the middle to the oil sump drain valve and the condenser service valve at the top of the condenser.
After the unit is off line for 10 minutes move the sightglass along the edge of the condenser tubesheet at the same height of the oil sump.
Enter the oil level from the bottom of the oil sump.
If the level is below 2”, there is not enough oil in the sump. This can occur from not enough oil in the system or more likely, oil migration to the evaporator. Oil migration can occur from a low refrigerant charge, gas pump malfunction, etc.
After the level is determined, close the service valves and remove the hose/sightglass assembly.
Sign off on the oil sump level check.
Oil Charging
Locate the 1/4” schrader valve between the ball valve and oil filter (or the ball valve and oil cooler, if so equipped).
Loosely connect oil pump to schrader valve.
Operate oil charging pump until oil appears at the charging valve connection; then tighten the connection.
Close the ball valve just upstream of the schrader valve connected to the oil pump.
At the UCP2 display panel, press <Service Tests> and enter the password (++--++) followed by <Enter>).
Press <enter> to access the service tools group.
Press <next> 12 times to display “Master Oil Line Solenoid Valve: [Mode]”.
Press ‘+’ to change the mode from “Auto” to “On”.
This will energize the solenoid to allow the oil to travel from the schrader to the compressor.
3 Yearly Series R™ Helical Rotary Chiller Maintenance
Use a nondestructive tube test to inspect the condenser and evaporator tubes at 3-year intervals.
NOTE: It may be desirable to perform tube tests on these components at more frequent intervals, depending upon chiller application. This is especially true of critical process equipment.
Depending on chiller duty, contact a qualified service organization to determine when to conduct a complete examination of the unit to determine the condition of the compressor and internal components.
Nondestructive tube test passed?
Describe any issues found during the tube test
Was the test performed at more frequent intervals?
Describe the condition of the compressor and internal components
Sign off on the 3 Yearly Series R™ Helical Rotary Chiller Maintenance
Compressor Oil Replacement
CAUTION: Due to the hygroscopic properties of the POE oil, all oil must be stored in metal containers. The oil will absorb water if stored in a plastic container.
Removing Compressor Oil
Is the service valve located on the bottom of the oil sump open?
Connect a line to the oil sump drain valve.
Is the valve open and allowing the desired amount of oil to flow into the container?
Close the charging valve.
Measure the exact amount of oil removed from the unit.
Sign off on the compressor oil replacement
Access the parts list for your equipment in MaintainX.
EXV
X15110743
Chiller
6200-0079-xx
Starter
6200-0055-xx
Options
6200-0040-xx
Stepper
6200-0081-xx
EXV
X15110743
Chiller
6200-0079-xx
Starter
6200-0055-xx
Options
6200-0040-xx
Stepper
6200-0081-xx
EXV
X15110743
Chiller
6200-0079-xx
Starter
6200-0055-xx
Options
6200-0040-xx
Stepper
6200-0081-xx
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX