MaintainX Logo
EnterprisePricing
Trane

Trane Series R™ Helical Rotary Chiller RTAC275X

Need answers fast?
Explore the manual using AI.

Trane Series R™ Helical Rotary Chiller RTAC275X
Trane Series R™ Helical Rotary Chiller RTAC275X

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Trane Series R™ Helical Rotary Chiller RTAC275X

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Trane Series R™ Helical Rotary Chiller RTAC275X

Trane Series R™ Helical Rotary Chiller RTAC275X

Create an account to install this asset package.

Maintenance Plans for Trane Series R™ Helical Rotary Chiller Model RTAC275X

Integrate maintenance plans directly into your work orders in MaintainX.

1 Monthly Series R™ Helical Rotary Chiller Maintenance

Check mark

Perform all weekly maintenance procedures

Check mark

Record the system subcooling

Check mark

Make any repairs necessary

Run this procedureArrow right

Refrigerant and Oil Charge Management

Check mark

Proper oil and refrigerant charge is essential for proper unit operation, unit perfor-mance, and environmental protection. Only trained and licensed service personnal should service the chiller.

Check mark

Some symptoms of a refrigerant under-charged unit:

Check mark

• Low subcooling

Check mark

• Higher than normal discharge superheat

Check mark

• Bubbles in EXV sight glass

Check mark

• Low liquid level diagnostic

Check mark

• Larger than normal evaporator approach temperatures (leaving water temperature - saturated evaporator temperature)

Check mark

• Low evaporator refrigerant temperature limit

Check mark

• Low refrigerant temperature cutout diagnostic

Run this procedureArrow right

Low Side Charge Isolation

Check mark

Circuit is off

Check mark

Suction line isolation valve is closed

Check mark

Oil return line service valve is closed

Check mark

Liquid line service valve is closed

Check mark

EXV is manually opened

Check mark

Select the method used to move refrigerant from the condenser to evaporator

Check mark

NOTE: If a pump is to be used, connect it before closing this valve. This port is only isolated when the valve is back seated. If a vacuum pump is used, then connect it to the discharge line service valve near the oil separator.

Check mark

Evaporator is large enough to hold all the charge for any unit to below the center-line of the shell

Check mark

Sign off on the Low Side Charge Isolation

Run this procedureArrow right

Neoprene Isolator Replacement

Check mark

Secure the isolators to the mounting surface using the mounting slots in the isolator base plate

Check mark

Align the mounting holes in the base of the unit with the threaded positioning pins on the top of the isolators

Check mark

Lower the unit onto the isolators and secure the isolator to the unit with a nut

Check mark

Enter the isolator deflection (should be 1/4 inch or 6 mm)

Check mark

Level the unit carefully

Check mark

Fully tighten the isolator mounting bolts

Check mark

Sign off on the isolator replacement

Run this procedureArrow right

High Side Charge Isolation

Check mark

Circuit is off

Check mark

Liquid line service valve is shut

Check mark

Oil return line service valve is shut

Check mark

Circuit started with the service tool (access compressor service view in Techview)

Check mark

Discharge check valve closed after unit trip

Check mark

Discharge isolation valve is closed

Check mark

Oil line shut off valve is closed

Check mark

Remainder of the refrigerant recovered

Check mark

NOTE: Remaining vapor can be recovered/stored in the high side of the system. Be certain to follow proper recovery procedures to avoid introduction of non-condensable gases.

Run this procedureArrow right

Parts for Trane Series R™ Helical Rotary Chiller RTAC275X

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Isolator

X10140305640

Isolator

X10140305640

Isolator

X10140305640

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Trane

Explore Other Assets