The Trane CenTraVac™ Water-Cooled Chiller CVHF model offers efficient cooling solutions for industrial applications. With a capacity range of 300-500 tons, this chiller is designed for reliability and performance, ensuring optimal operation in various environments. Regular maintenance is essential for longevity and efficiency.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Trane CenTraVac™ Water-Cooled Chiller CVHF - 300-500 - 379 - 050S / 080S
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Chiller Maintenance
Chiller's evaporator pressure
Chiller's condenser pressure
Oil tank pressure
Differential oil pressure
Discharge oil pressure
Are the readings within the values provided in the general maintenance?
Is the oil level visible in the lower sight glass when the unit is operating?
Sign off on the daily chiller maintenance
3 Yearly Tubes Maintenance
Use a non-destructive tube test to inspect the condenser and evaporator tubes
Tube test performed on condenser?
Tube test performed on evaporator?
It may be desirable to perform tube tests on these components at more frequent intervals depending upon chiller application
This is especially true of critical process equipment
Ask your Sales account manager for a copy of engineering bulletin (CTV-PRB024*-EN) for clarification of the role of eddy current testing in chiller maintenance by providing information about eddy current technology and heat exchanger tubing
Sign off on the tube maintenance
1 Yearly Chiller Leak Test
WARNING: Explosion Hazard! Never use an open flame to detect gas leaks. Use a leak test solution for leak testing.
WARNING: Hazardous Pressures! If a heat source is required to raise the tank pressure during removal of refrigerant from cylinders, use only warm water or heat blankets to raise the tank temperature. Do not exceed a temperature of 150°F. Do not under any circumstances apply direct flame to any portion of the cylinder.
Important: If leak testing is required, contact a Trane Service Agency;
Shut down the chiller
Check purge times and unit performance logs
Review oil analysis
Submit refrigerant sample for analysis if required
Inspect unit for any signs of refrigerant or oil leakage
Check unit for any loose screws on flange, volutes, or casing
3 Yearly Evaporator Maintenance
Clean Evaporator
Is the evaporator part of a closed circuit?
If the evaporator is part of a closed circuit, it may not accumulate appreciable amounts of scale or sludge.
Has it been three years since the last cleaning?
Normally, cleaning every three years is sufficient.
Is the evaporator part of an open system, such as air washers?
However, periodic inspection and cleaning is recommended on open evaporator systems, such as air washers.
Sign off on the evaporator maintenance
1 Yearly Chiller Maintenance
Annual Maintenance Procedures
Select the type of chiller
Evaporator refrigerant temperature sensor (4R10) reading
Is the sensor reading within the normal operating range (0°F to 90°F [-17.8°C to 32.2°C])?
Are the condenser tubes clean?
Are the ifm efector® flow detection sensors clean?
Upload a photo of the compressor oil sample sent to the Trane-qualified laboratory
Compressor motor winding resistance to ground
Did the chiller pass the leak-test?
Access the parts list for your equipment in MaintainX.
Safety Hoist Ring 1/2-13, CTV Unit
RNG01885
Safety Hoist Ring 3/4-10, CTV Unit
RNG01884
Evap Lifting Fixture, CTV Unit
BAR00400
Safety Hoist Ring 1/2-13, CTV Unit
RNG01885
Safety Hoist Ring 3/4-10, CTV Unit
RNG01884
Evap Lifting Fixture, CTV Unit
BAR00400
Safety Hoist Ring 1/2-13, CTV Unit
RNG01885
Safety Hoist Ring 3/4-10, CTV Unit
RNG01884
Evap Lifting Fixture, CTV Unit
BAR00400
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX