MaintainX Asset Hub logo
EnterprisePricing
Thermo Fisher

Thermo Fisher Hot Plate HPA1910M

Need answers fast?
Explore the manual using AI.

Thermo Fisher Hot Plate HPA1910M
Thermo Fisher Hot Plate HPA1910M

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Thermo Fisher Hot Plate HPA1910M

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Thermo Fisher Hot Plate HPA1910M

Thermo Fisher Hot Plate HPA1910M

Create an account to install this asset package.

Maintenance Plans for Thermo Fisher Hot Plate Model HPA1910M

Integrate maintenance plans directly into your work orders in MaintainX.

Hot Plate Control Unit Replacement

Check mark

Warning!

Check mark

Control Unit Replacement Steps

Check mark

Disconnect hot plate from power supply.

Check mark

Turn hot plate upside down and remove perforated cover.

Check mark

Remove stop collar by loosening set screw and remove the adjusting shaft from case.

Check mark

Disconnect heater coil from control contact stud and disconnect white insulated wire from control unit.

Check mark

Remove two screws holding control on top plate and remove control unit.

Check mark

Install new control unit and secure with two screws.

Check mark

Reinsert adjusting shaft and stop collar.

Run this procedureArrow right

Hot Plate Cycle Light Replacement

Check mark

Warning!

Check mark

Cycle Light Replacement Steps

Check mark

Disconnect hot plate from power supply.

Check mark

Turn hot plate upside down and remove perforated cover.

Check mark

Disconnect two leads from cycle light.

Check mark

Push in two clips on cycle light and remove cycle light by pulling it out from the front.

Check mark

Insert new cycle light through the front and reconnect leads to the proper terminals.

Check mark

Replace perforated cover.

Check mark

Turn hot plate upright and reconnect to power supply.

Run this procedureArrow right

Hot Plate Heater Coil Replacement

Check mark

Warning

Check mark

Refer servicing to qualified personnel.

Check mark

Caution: Hot Surface. Avoid Contact.

Check mark

To Replace Heater Coil

Check mark

Disconnect hot plate from power supply.

Check mark

Turn hot plate upside down and remove perforated cover.

Check mark

Remove nut and washer from contact stud, then remove one end of heater coil.

Check mark

Remove remaining nut holding heater coil and remove heater coil.

Check mark

Install new heater coil and secure with two nuts. Space approx. 1/8" from bimetal strip.

Run this procedureArrow right

Hot Plate Calibration

Check mark

Warning! Refer servicing to qualified personnel.

Check mark

Caution: Hot Surface. Avoid Contact.

Check mark

The hot plate will remain hot for some time after the power is turned off.

Check mark

Recalibration Procedure

Check mark

Disconnect hot plate from power supply.

Check mark

Turn hot plate upside down and remove perforated cover.

Check mark

Remove the knob from the adjusting shaft by removing set screw.

Check mark

Turn the shaft until the contacts just close and slide knob over with the pointer in line with the FIRST mark on the dial plate.

Check mark

Tighten the knob to the shaft with about 3/16" between skirt of the knob and the dial plate.

Run this procedureArrow right

Hot Plate Element Replacement

Check mark

Warning! Refer servicing to qualified personnel.

Check mark

Caution: Hot Surface. Avoid Contact.

Check mark

Element Replacement Steps

Check mark

Disconnect hot plate from power supply.

Check mark

Turn hot plate upside down and remove perforated cover.

Check mark

Remove stop collar by loosening set screw and remove the adjusting shaft.

Check mark

Disconnect the necessary wires to enable the case section to be removed.

Check mark

Remove case section from heating plate.

Check mark

Slide two metal plates off the element lead wires with the insulators.

Run this procedureArrow right

Parts for Thermo Fisher Hot Plate HPA1910M

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Plate Aluminum Top

PT27X1

Element For HPA1910M 240V

EL27X2

Control

CN19X3

Shaft Control Adjustment

SF25X1

Cord Set For HPA1910M 240V

CR242X1

Plate Aluminum Top

PT27X1

Element For HPA1910M 240V

EL27X2

Control

CN19X3

Shaft Control Adjustment

SF25X1

Cord Set For HPA1910M 240V

CR242X1

Plate Aluminum Top

PT27X1

Element For HPA1910M 240V

EL27X2

Control

CN19X3

Shaft Control Adjustment

SF25X1

Cord Set For HPA1910M 240V

CR242X1

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Thermo Fisher

Explore Other Assets