Teledyne CETAC Technologies Autosampler ASX-1400
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Autosampler Cleaning
Preparation
Shut down and unplug the autosampler
Cleaning Process
Wipe the sample tray, autosampler cabinet, and autosampler arm with a towel dampened with a laboratory-grade cleaning liquid
Wipe again with a towel dampened with clear water
Dry the sample tray, autosampler cabinet, and autosampler arm with a dry towel
Safety Precautions
Ensure no liquid entered the instrument cabinet or contacted electrical components
Final Check
1 Weekly Autosampler Cleaning
Preparation
Shut down the autosampler
Unplug the autosampler
Cleaning the Autosampler
Remove the sample tray
Wipe loose particles off the Y-Axis lead screw with a dry, lint-free cloth
Wipe the autosampler exterior and base with a towel dampened with laboratory-grade cleaning liquid
Wipe the autosampler exterior and base with a towel dampened with clear water
Pay special attention to the Y-axis slider block and guide rails
Peristaltic Pump Tubing Replacement
Preparation
Shut down the autosampler
Unplug the autosampler
Remove Old Tubing
Release the pressure shoe
Remove the old tubing
Did you need to cut the old tubing to remove it?
Install New Tubing
Push the new tubing onto the fittings
Autosampler Check
Preparation
Shut down the autosampler
Unplug the autosampler
Inspection for Leaks and Deterioration
Visually inspect the following parts for leaks or signs of deterioration
Post-Inspection Actions
Did you detect any leaks or damage to an autosampler part?
Replace any damaged or leaking parts
Rinse Station Tubing Replacement
Preparation
Shut down and unplug the autosampler
Move the autosampler arm 20 to 30 centimeters away from the home position
Tubing Disconnection
Disconnect the rinse agent uptake and drain tubing
Apply only a linear force when removing the tubing to prevent fittings from breaking
Remove Old Tubing
Rotate the rinse station tube counterclockwise ¼ turn
Lift the tube straight up
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX