MaintainX Asset Hub logo
EnterprisePricing
SULLAIR

SULLAIR Vacuum System VS32-150/A

Need answers fast?
Explore the manual using AI.

SULLAIR Vacuum System VS32-150/A
SULLAIR Vacuum System VS32-150/A

The Sullair Vacuum System VS32-150/A is a robust industrial vacuum solution designed for efficient operation in various applications. Known for its reliability and performance, this model ensures optimal vacuum levels while minimizing maintenance needs, making it an ideal choice for demanding environments.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

SULLAIR Vacuum System VS32-150/A

SULLAIR Vacuum System VS32-150/A

Create an account to install this asset package.

Maintenance Plans for SULLAIR Vacuum System Model VS32-150/A

Integrate maintenance plans directly into your work orders in MaintainX.

1000 Hourly / 6 Monthly Fluid Filter Maintenance

Check mark

Warning: Only use a replacement fluid filter identified with the Sullair name, logo and appropriate part number.

Check mark

Old element and gasket removed with a strap wrench?

Check mark

Gasket seating surface cleaned?

Check mark

Light film of fluid applied to the new gasket?

Check mark

New element hand tightened until new gasket is seated in the gasket groove without any nicks, cuts or pinches?

Check mark

Element tightened by hand an additional 1/2 to 3/4 turn?

Check mark

Vacuum restarted and checked for leaks?

Check mark

Sign off on the fluid filter maintenance

Run this procedureArrow right

4000 Hourly Vacuum System Maintenance

Check mark

Warning: Drainage and fill-up of lubricant from the cooler core must be done separately from the separator tank; the thermal valve isolates the connecting pipework. Please use the provided filler (outlet manifold), drain (outlet manifold) and breather (inlet manifold) plugs for these tasks.

Check mark

Cleaned the return line strainer?

Check mark

Lubricated the Sullicon Control linkage?

Check mark

Drained the sump and changed the vacuum pump fluid?

Check mark

Sign off on the 4000 Hourly Vacuum System Maintenance

Run this procedureArrow right

6 Monthly Inlet Air Filter Maintenance

Check mark

Air filter maintenance should be performed every six (6) months or when indicated by the inlet vacuum gauges.

Check mark

Clean exterior of air filter housing.

Check mark

Remove the air filter cover by loosening the clamps securing the cover.

Check mark

Clean debris from inside filter housing prior to removing element.

Check mark

Remove element and clean the base and interior of cover using a damp cloth. DO NOT blow dirt out with compressed air.

Check mark

At this time, replace the element.

Check mark

Replace cover.

Check mark

Sign off on the air filter maintenance

Run this procedureArrow right

Control System Adjustment

Check mark

Warning: This procedure requires trained personnel!

Check mark

Enter the current operating vacuum

Check mark

Is the operating vacuum at 20 in-Hg (508mm)?

Check mark

If not, adjust the vacuum regulator

Check mark

Is the jam nut on the vacuum regulator loose?

Check mark

If not, loosen the jam nut

Check mark

Did you adjust the screw clockwise to increase the setting or counterclockwise to decrease the setting?

Check mark

Enter the new operating vacuum

Check mark

Is the new operating vacuum at 20 in-Hg (508mm)?

Run this procedureArrow right

Element Inspection

Check mark

Place a bright light inside the element to inspect for damage or leak holes. Concentrated light will shine through the element and disclose any faulty areas.

Check mark

Inspect all gaskets and gasket contact surfaces of the housing. Should faulty gaskets be evident, correct the condition immediately.

Check mark

If the clean element is to be stored for later use, it must be stored in a clean container.

Check mark

After the element has been installed, inspect and tighten all air inlet connections prior to resuming operation.

Check mark

Sign off on the element inspection

Run this procedureArrow right

Parts for SULLAIR Vacuum System VS32-150/A

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

90 Sae X Orfs 1.25”

02250087-071

Adapter, Air Inlet

250022-606

Adaptor, Venturi Panel 25-200

02250152-003

Angle, 2 X 2 X 2/15 1/2 25/200

250022-720

Angle, Formed 1-1/4 X 2-1/4

232876

90 Sae X Orfs 1.25”

02250087-071

Adapter, Air Inlet

250022-606

Adaptor, Venturi Panel 25-200

02250152-003

Angle, 2 X 2 X 2/15 1/2 25/200

250022-720

Angle, Formed 1-1/4 X 2-1/4

232876

90 Sae X Orfs 1.25”

02250087-071

Adapter, Air Inlet

250022-606

Adaptor, Venturi Panel 25-200

02250152-003

Angle, 2 X 2 X 2/15 1/2 25/200

250022-720

Angle, Formed 1-1/4 X 2-1/4

232876

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from SULLAIR

Explore Other Assets