

The Starrett Horizontal Digital Video System HDV400 is a high-precision measurement tool designed for industrial applications. This advanced system integrates digital video technology to enhance accuracy and efficiency in measurement tasks, making it an essential asset for quality control and inspection processes.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Starrett Horizontal Digital Video System HDV400
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Horizontal Digital Video System Inspection
Verify that the work area is clean, dry and free of debris
Verify that the electrical power cord is plugged into a grounded power source and is unobstructed
Verify that temperature is within recommended range
Verify that humidity is within recommended range
Allow the system to warm up to normal operating temperature before performing critical parts measurements
Sign off on the daily inspection
1 Monthly Calibration Verification
Calibration should be verified periodically depending on user requirements, system usage, and should be performed at least monthly.
Calibration should also be verified after the system has been serviced or moved.
A chrome-on-glass calibration verification standard artifact is available from Starrett or its authorized distributors.
This standard has a length of 300 millimeters and major calibration fiducials spaced every 25 millimeters.
Place the calibrated standard along the X-axis. Secure the standard to the stage with a holder (available from Starrett).
Skew the center of the two end circles of the calibration standard. Refer to the M3 Software User Guide for proper alignment procedure.
Using the HDV system, measure the position of fiducials spaced every 25 millimeters. For each fiducial, take the average of multiple readings for improved accuracy.
Calculate the absolute measurement error for each fiducial by subtracting the calibrated position of the fiducial from the above average readings.
Verify that the calculated absolute X measurement errors are within the HDV system accuracy specification, which is E2 = 3.0 µm + 1 µm x L/(33 mm).
1 Monthly Fan Filter Maintenance
• In a standard HDV configuration, the side of the housing includes a 4.7 inch (120 mm) fan that draws in ambient air through a filter and maintains a slightly positive pressure inside the housing. While the system is running, the air that comes in contact with the electronics has passed through this filter.
• Inspect the fan filter for cleanliness at least monthly. Fan filters and the fan itself are userreplaceable items. The filters and fan are available from electronics distributors and in computer stores. When purchasing a new fan, ensure that the voltage is 24V, as marked on the previous fan.
• To inspect the fan filter, refer to the following figure and perform the following steps:
1. Pry off the fan bezel with a flat-blade screwdriver and remove the filter, which is held by the bezel.
2. Inspect the fan filter. If the filter is dirty, it can be washed in hot water or be replaced.
3. To reinstall the filter, reseat it in the bezel and press the bezel back in place.;
1 Monthly Zoom Optics Parcentricity Check
Parcentricity describes the condition where a feature remains at the optical center of the video image throughout the magnification range. Like parfocality, parcentricity requires that the feature be first located at highest magnification.
Place the MAG checker or other suitable inspection part on the stage and secure properly.
Is the crosshair image tool at its defined center position?
Zoom to low magnification and adjust the stage position so that the crosshair is centered on the X-Y axis of the calibration standard (or another suitable feature if the standard is not used).
Change to high magnification and refocus the image.
Adjust the stage position as needed to recenter the crosshair on the feature.
Does the feature remain at the center of the crosshair as the magnification is lowered?
Report any observed discrepancy.
If the error is verified, contact your Starrett representative for authorized service.
1 Monthly Zoom Optics Parfocality and Focus Check
Parfocality is the condition in which the video image remains in focus as the magnification is adjusted from highest to lowest. Starrett zoom optics are designed to maintain parfocality throughout their magnification range. To check parfocality, always reference a flat, sharp edge. Do not select a rough or sloping feature. The magnification (Mag) checker provided with the system is an ideal part to check parfocality.
MAG checker or other suitable inspection part is placed on the stage and secured properly
Backlight the image as necessary. Light levels are set as needed to avoid blooming
At low magnification, a flat, sharp edge in the center of the field of view (FOV) is selected
At highest magnification, the image is refocused by physically changing the viewing distance
While observing the feature, the magnification is slowly adjusted lower. The feature remains focused as the magnification is lowered
Report any observed discrepancy
If the error is verified, contact your Starrett representative for authorized service
Sign off on the parfocality and focus check
Access the parts list for your equipment in MaintainX.
300 Mm Line Standard
4422-1
400 Mm Line Standard
5584-1
Cabinet Stand 22-Inch High
8171
Cabinet Stand 31-Inch High
8170
Calibration Standard Fixture
7430
300 Mm Line Standard
4422-1
400 Mm Line Standard
5584-1
Cabinet Stand 22-Inch High
8171
Cabinet Stand 31-Inch High
8170
Calibration Standard Fixture
7430
300 Mm Line Standard
4422-1
400 Mm Line Standard
5584-1
Cabinet Stand 22-Inch High
8171
Cabinet Stand 31-Inch High
8170
Calibration Standard Fixture
7430
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













