The Starrett Vision Metrology System AV450 is a precision optical measurement tool designed for high accuracy in industrial applications. This advanced system offers reliable performance and is essential for quality control and inspection processes in manufacturing environments.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Starrett Vision Metrology System AV450
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Vision Metrology System Inspection
Area around the system has proper clearance
No debris or loose items around the system and the metrology stage
Work area is clean, dry and free of debris
Electrical power cord is plugged into a grounded power source and is unobstructed
Environmental conditions (temperature and humidity) are within recommended ranges
System has warmed up to normal operating temperature before performing critical part measurements
Stage control mechanisms move freely
On CNC Systems, zoom mechanism operates freely through the software
1 Monthly Calibration Verification
Calibration should be verified periodically depending on user requirements and systems usage, and should be at least monthly.
Calibration should also be verified after the system has been serviced or moved.
The following is a brief description of the steps recommended for the verification of your machine.
Place the calibrated verification standard in one the six positions on the glass stage as shown above. Secure the standard with hot melt glue or other suitable retaining method so that stage translation can not move the standard under any condition.
Skew the center of the two end circles. Please refer to the M3 manual for proper alignment procedures.
Measure the distance between the 1st and 2nd, 1st and 3rd, 1st and 4th, 1st and 5th, and the 1st and 6th fiducials. Repeat these measurements 10 times.
Calculate the absolute average deviation for each of the 5 groups of distance measurements.
Repeat the measurements for all six locations shown in the illustration.
The absolute averages should be within the factory specification, de-rated for the environment and calibration accuracy. See Table 1 - 5, “Travel, Accuracy and Resolution Specifications” for accuracy specifications.
6 Monthly Lead-Screw Lubrication
Warning: Use only approved lubricants, as inappropriate lubricants can damage system components.
Is the lubricant Tri-Flow®?
If the lubricant is not Tri-Flow®, stop the procedure and contact Starrett or an authorized Starrett representative.
Enter the amount of Tri-Flow® used
Did you traverse the stage or column through the entire range of travel several times to distribute the lubricant?
Did you use a clean soft cloth or paper towel to wipe up any excess?
Sign off on the lubrication process
6 Monthly Vision Metrology System Calibration
Warning: Only authorized Starrett technicians should perform this service
System functioning properly?
Enter the system's usage hours
Is the system under heavy usage?
If system is under heavy usage, it may require more frequent service
Technician's signature
Auxiliary Lens Replacement
Warning: Avoid touching any lens surfaces during the procedure.
Ring light removed prior to changing the lens?
If an auxiliary lens is in place, was it unscrewed counterclockwise?
Are the new lens and exposed lens of the primary optics assembly clean and dust free?
Was the aux lens carefully screwed in clockwise, finger-tight only?
Was the lens setting updated in the QC5000 software?
Upload a photo of the installed lens.
Sign off on the lens replacement
Access the parts list for your equipment in MaintainX.
Stage Glass
5485
Stage Glass
5485
Stage Glass
5485
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX