Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Scott Self-Contained Breathing Apparatus SKA-PAC
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Regulator Check
NOTE: THIS REGULATOR CHECK IS NOT INTENDED TO BE A COMPLETE FUNCTIONAL CHECK OF THE RESPIRATOR. BEFORE NEXT USE, PERFORM A REGULAR OPERATIONAL INSPECTION AS DESCRIBED IN THESE INSTRUCTIONS.
Respirator cylinder is at least 1/4 full
Donning/air saver switch is fully depressed
Purge knob is closed
Regulator is reattached to the respirator (if removed for cleaning)
Cylinder valve is opened at least one (1) full turn
No air flow from the regulator is heard
If air flow from the regulator is heard, close the cylinder valve, repeat steps 1, 2 and 3. If air flow is still heard, close the cylinder valve fully, tag unit for repair and remove from service.
Open the purge valve and observe the air flow from the regulator spray bar. No droplets of water are present
2 Yearly Respirator Maintenance
Warning: Only SCOTT Authorized Service Center personnel should perform this check
Respirator visually checked
Respirator functionally checked
Upload the maintenance manual
Sign off on the respirator maintenance
Respirator Maintenance
Warning: Do not attempt to replace components or make adjustments or repairs without proper training.
Inspect the equipment for worn or aging rubber parts, worn or frayed harness webbing or damaged components.
If the SKA-PAK PLUS respirator is equipped with the full body/fall protection harness, inspect the harness for frayed or damaged webbing or damaged buckles.
If any damage to the harness is found, do not use the full body/fall protection harness.
Remove the breathing regulator from the facepiece by pulling back on the regulator retaining latch and rotating the regulator 1/4 turn.
Clean the respirator according to CLEANING THE RESPIRATOR section of this instruction. The unit must be thoroughly dry before storage.
Inspect the gasket on the breathing regulator that seals against the facepiece for rips or damage that may break the seal.
Connect the breathing regulator to the facepiece and rotate until it latches into place. Verify that the latch securely snaps into the notch on the facepiece.
Perform the REGULAR OPERATIONAL INSPECTION described in this instruction manual.
Respirator Inspection
Respirator visually complete
Harness inspected for damage
Cylinder valve closed
Trapped air vented from system
Cylinder hydrostatic test date current
Cylinder and valve assembly inspected for physical damage
Cylinder gauge indicates 'FULL'
Cylinder attachment to the harness inspected
Full body/fall protection harness inspected for damage
Mask Mounted Regulator Cleaning
NOTE: AFTER CLEANING THE REGULATOR, VERIFY THAT ALL MOISTURE HAS BEEN REMOVED FROM THE REGULATOR AS DESCRIBED IN THE REGULATOR CHECK SECTION OF THIS INSTRUCTION.
Remove the breathing regulator from the facepiece by pulling back on the locking clip and rotating the regulator 1/4 turn clockwise.
Remove any obvious dirt from the external surfaces of the regulator using SCOTT recommended sanitizing or disinfecting cleaner with a sponge or soft cloth.
Inspect the inside of the regulator assembly through the regulator opening. If excessive dirt or soil is present, forward regulator assembly to SCOTT trained authorized personnel for thorough cleaning.
Depress the donning/air saver switch, close the purge knob by turning fully clockwise. Use the SCOTT recommended sanitizing or disinfecting cleaner in the regulator opening and the immediate area around the opening. Be sure to cover internal components completely.
Follow the user instructions for the SCOTT recommended cleaner. A specific contact time may be required for sanitizing or disinfecting before rinsing.
Rinse the regulator with drinking water using a spray bottle or gently running tap water.
Shake excess water out of regulator. Completely air dry the regulator before use.
NOTE: TO SPEED DRYING OF THE REGULATOR, GENTLY BLOW DRY WITH CLEAN, DRY BREATHING AIR OF 30 PSIG MAXIMUM. DO NOT USE SHOP AIR OR ANY OTHER AIR CONTAINING LUBRICANTS OR MOISTURE.
Access the parts list for your equipment in MaintainX.
Fit Test Adapter
804057-01
Mask Seal Kit
805655-01
Sureseal Face Seal (Small)
31001738
Sureseal Face Seal (Medium)
31001739
Sureseal Face Seal (Large)
31001740
Fit Test Adapter
804057-01
Mask Seal Kit
805655-01
Sureseal Face Seal (Small)
31001738
Sureseal Face Seal (Medium)
31001739
Sureseal Face Seal (Large)
31001740
Fit Test Adapter
804057-01
Mask Seal Kit
805655-01
Sureseal Face Seal (Small)
31001738
Sureseal Face Seal (Medium)
31001739
Sureseal Face Seal (Large)
31001740
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX