MaintainX Asset Hub logo
EnterprisePricing
Rosemount

Rosemount Electronic Remote Sensor 3051S2

Need answers fast?
Explore the manual using AI.

Rosemount Electronic Remote Sensor 3051S2
Rosemount Electronic Remote Sensor 3051S2

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Rosemount Electronic Remote Sensor 3051S2

Rosemount Electronic Remote Sensor 3051S2

Create an account to install this asset package.

Maintenance Plans for Rosemount Electronic Remote Sensor Model 3051S2

Integrate maintenance plans directly into your work orders in MaintainX.

Analog Output Trim Adjustment

Check mark

Launch the Analog Trim function using AMS Device Manager or a communication device.

Check mark

Connect a reference milliamp meter to the 4–20 mA output of the primary sensor. Connect the positive lead to the positive terminal and the negative lead to the test terminal.

Check mark

The Analog Trim function will then force the analog output of the ERS System to 4 mA.

Check mark

Enter the mA reading from the reference meter

Check mark

If the reference meter reads “4 mA,” select YES

Check mark

If the reference meter still does not read “4 mA,” select NO, and repeat Step 3.

Check mark

Repeat Step 3 and Step 4 for the 20 mA output.

Check mark

Sign off on the Analog Output Trim Adjustment

Run this procedureArrow right

DP Adjustment

Check mark

Warning: DP calibration functions must be performed after completing the calibration functions on the individual PHI and PLO sensors.

Check mark

PHI and PLO sensors calibrated?

Check mark

Zero trim for PHI and PLO eliminates the DP offset.

Check mark

Zero trim for PHI and PLO performed?

Check mark

Performing a zero DP trim will establish a new DP zero point.

Check mark

Zero DP trim performed?

Check mark

Differential pressure (DP) zero trim

Check mark

DP zero trim function established?

Check mark

Upper and lower DP trims

Run this procedureArrow right

Electronic Remote Sensor Calibration

Check mark

This section contains information on commissioning and operating a 3051S Electronic Remote Sensor (ERS) System.

Check mark

Instructions for performing operation and maintenance functions are given for a communication device. For convenience, communication device Fast Key sequences are labeled “Fast Keys” for each software function below the appropriate headings.

Check mark

Calibrating a Rosemount ERS System involves the following tasks:

Check mark

Procedure

Check mark

1. Configure process variables.

Check mark

See Basic setup for additional details on configuring the following:

Check mark

• Units of measure

Check mark

• Damping

Check mark

• Variable mapping

Run this procedureArrow right

Electronics Removal

Check mark

Remove the housing cover opposite the field terminal side

Check mark

Remove the LCD display by holding in the two clips and pulling outward

Check mark

Loosen the two small screws located on the assembly in the 8 o’clock and 2 o’clock positions

Check mark

Pull out the assembly to expose the SuperModule™ connector

Check mark

Grasp the SuperModule connector and pull upwards (avoid pulling wires)

Check mark

Housing rotation may be required to access locking tabs

Check mark

Sign off on the electronics removal

Run this procedureArrow right

Functional Test

Check mark

Warning: This test requires trained personnel!

Check mark

Upload a photo of the connected reference meter to the ERS System

Check mark

Was the loop test function launched successfully?

Check mark

Enter the mA value output on the 4-20 mA loop

Check mark

Enter the reading from the reference meter

Check mark

Do the values match?

Check mark

If the values do not match, select the possible issues

Check mark

Sign off on the functional test

Run this procedureArrow right

Parts for Rosemount Electronic Remote Sensor 3051S2

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Rosemount O-Rings

03151-9040-0001

Rosemount O-Rings

03151-9040-0001

Rosemount O-Rings

03151-9040-0001

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Rosemount

Explore Other Assets