MaintainX Asset Hub logo
EnterprisePricing
Pentair

Pentair Centrifugal Pump P6RAA6F-216L

Need answers fast?
Explore the manual using AI.

Pentair Centrifugal Pump P6RAA6F-216L
Pentair Centrifugal Pump P6RAA6F-216L

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Pentair Centrifugal Pump P6RAA6F-216L

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Pentair Centrifugal Pump P6RAA6F-216L

Pentair Centrifugal Pump P6RAA6F-216L

Create an account to install this asset package.

Maintenance Plans for Pentair Centrifugal Pump Model P6RAA6F-216L

Integrate maintenance plans directly into your work orders in MaintainX.

Drain Cover Inspection

Check mark

WARNING

Check mark

Describe any observed cracks, damage, or advanced weathering on the covers

Check mark

Is any cover loose, cracked, damaged, broken, or missing?

Check mark

Immediate Actions if Issues Found

Check mark

Close the pool or spa immediately

Check mark

Shut off the pump

Check mark

Post a notice about the closure

Check mark

Keep the pool or spa closed until an appropriate certified cover is properly installed

Check mark

Check the condition of all suction outlet covers

Run this procedureArrow right

Pump Draining

Check mark

Initial Safety Precautions

Check mark

Is the power to the motor turned OFF before draining the pump?

Check mark

Draining the Pump

Check mark

Pump down water level below all inlets to the pool.

Check mark

Remove trap cover and use low pressure air to blow accumulated water from the piping system.

Check mark

Cap inlet piping after draining to keep water out of the pipes.

Check mark

Preventing Freezing

Check mark

Remove trap cover and drain the tank body through the drain plugs.

Check mark

Clean pump and trap basket thoroughly; replace trap cover.

Run this procedureArrow right

Pump Maintenance

Check mark

WARNING

Check mark

Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, filter, or piping.

Check mark

Ensure pump does not freeze to avoid damage and voiding warranty.

Check mark

Do not use anti-freeze solutions (except propylene glycol) in your pool/spa system.

Check mark

Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time.

Check mark

Keep motor dry and covered during storage.

Check mark

Avoid covering pump with plastic to prevent condensation/corrosion problems.

Check mark

Outdoor/Unprotected Installations

Check mark

Gravity drain system as far as possible.

Run this procedureArrow right

Trap Basket Cleaning

Check mark

Safety Precautions

Check mark

Ensure the strainer pot temperature is cool to touch before opening.

Check mark

Confirm suction and discharge valves are open before opening the strainer pot.

Check mark

Preparation

Check mark

Stop pump and close valves in suction and discharge.

Check mark

Release all pressure from the system.

Check mark

Trap Basket Cleaning

Check mark

Remove trap cover handle ring by turning counterclockwise. Tap handles gently with a rubber mallet if necessary.

Check mark

Remove strainer basket and clean. Ensure all holes in basket are clear and flush basket with water.

Run this procedureArrow right

Parts for Pentair Centrifugal Pump P6RAA6F-216L

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

#10-32x1/2" Screw

U30-692SS

Lock Washer

U43-22SS

Bonding Lug

U17-568

Water Slinger

17351-0009

Seal Plate Kit (Includes O-Ring And Shaft Seal)

354444Z

#10-32x1/2" Screw

U30-692SS

Lock Washer

U43-22SS

Bonding Lug

U17-568

Water Slinger

17351-0009

Seal Plate Kit (Includes O-Ring And Shaft Seal)

354444Z

#10-32x1/2" Screw

U30-692SS

Lock Washer

U43-22SS

Bonding Lug

U17-568

Water Slinger

17351-0009

Seal Plate Kit (Includes O-Ring And Shaft Seal)

354444Z

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Pentair

Explore Other Assets