MaintainX Logo
EnterprisePricing
Peerless Pump Company

Peerless Pump Company Vertical Turbine Industrial Pumps Open Line Shaft 36-HH

Need answers fast?
Explore the manual using AI.

Peerless Pump Company Vertical Turbine Industrial Pumps Open Line Shaft 36-HH
Peerless Pump Company Vertical Turbine Industrial Pumps Open Line Shaft 36-HH

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Peerless Pump Company Vertical Turbine Industrial Pumps Open Line Shaft 36-HH

Peerless Pump Company Vertical Turbine Industrial Pumps Open Line Shaft 36-HH

Create an account to install this asset package.

Maintenance Plans for Peerless Pump Company Vertical Turbine Industrial Pumps Open Line Shaft Model 36-HH

Integrate maintenance plans directly into your work orders in MaintainX.

2000 Hourly / 3 Monthly Packing Box Inspection

Check mark

Warning: This inspection requires trained personnel with PPE!

Check mark

Packing, packing box inspection

Check mark

Inspect for excessive leakage

Check mark

Report any problems found during the inspection

Check mark

Sign off on the packing box inspection

Run this procedureArrow right

Vertical Turbine Industrial Pumps Open Line Shaft Maintenance

Check mark

Warning: Drain the pump and isolate pipework before dismantling the pump.

Check mark

Warning: There may be occasions when a part such as the impeller has either been shrunk-fit onto the pump shaft or has become difficult to remove due to products that are corrosive in nature.

Check mark

Warning: Before opening the terminal box of an electric motor, make sure that the power supply has been switched off.

Check mark

Drained the pump and isolated pipework?

Check mark

Removed impeller with care, ensuring any residual hazardous liquid is thoroughly drained out?

Check mark

Contact details of Peerless Pump for help in removal of impellers

Check mark

Cleared a large area adjacent to the pump as a storage space for pump parts as they are dismantled?

Check mark

Arranged parallel timbers on the ground in the cleared area to support the pump column and shaft sections horizontally?

Check mark

Disconnected the discharge pipe from the discharge head?

Run this procedureArrow right

1 Yearly Vertical Turbine Industrial Pumps Open Line Shaft Check

Check mark

Warning: This check requires trained personnel with PPE!

Check mark

Pump-motor alignment: Check for change in alignment

Check mark

Vibration: Check for change in vibration

Check mark

Fasteners: Check for loose fasteners

Check mark

Report any problems found during the inspection

Check mark

Sign off on the pump inspection

Run this procedureArrow right

Packing Box Maintenance

Check mark

Warning: This maintenance check requires trained personnel with PPE!

Check mark

To ensure satisfactory operation of the pumping equipment, frequent inspection and periodic maintenance are required.

Check mark

An inspection and maintenance log should be kept and the inspector is to immediately report any problems.

Check mark

Unusual applications with abnormal heat, moisture, dust, etc., may require more frequent inspection and service.

Check mark

Packing box in good condition?

Check mark

Report any problems found during inspection

Check mark

Gland adjusted properly?

Check mark

Packing replaced successfully?

Check mark

Sign off on the packing box maintenance

Run this procedureArrow right

Initial 150 Hours Packing Box Inspection

Check mark

To ensure satisfactory operation of the pumping equipment, frequent inspection and periodic maintenance are required.

Check mark

An inspection and maintenance log should be kept and the inspector is to immediately report any problems.

Check mark

A suggested guide for preventative maintenance for normal applications is given below.

Check mark

Unusual applications with abnormal heat, moisture, dust, etc., may require more frequent inspection and service.

Check mark

Packing box inspected for excessive leakage?

Check mark

Describe the condition of the packing box

Check mark

Inspector's signature

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Peerless Pump Company

Explore Other Assets