Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Liftmaster Single Arm Package LA500UL
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
6 Monthly Single Arm Package Maintenance
Check and test manual release for proper operation
Check all accessories for proper operation
Inspect all electrical wire connections
Check Mounting Hardware for tightness
Inspect operator for wear or damage
WARNING! READ AND FOLLOW ALL INSTRUCTIONS
ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service
Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes. NOTE: The operator should be on a separate fused line of adequate capacity
NEVER let children operate or play with gate controls. Keep the remote control away from children.
3 Yearly Battery Replacement
WARNING! READ AND FOLLOW ALL INSTRUCTIONS
ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch.
Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service
Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes.
NEVER let children operate or play with gate controls. Keep the remote control away from children.
ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE
The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance
Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact sensors.
Use the manual disconnect release ONLY when the gate is NOT moving
1 Monthly Single Arm Package Maintenance
WARNING! READ AND FOLLOW ALL INSTRUCTIONS
ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch.
Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service
Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes.
NEVER let children operate or play with gate controls. Keep the remote control away from children.
ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE
The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance
Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact sensors.
Use the manual disconnect release ONLY when the gate is NOT moving
Access the parts list for your equipment in MaintainX.
Standard Plastic Control Box
K74-39307-1
Outlet
K76-36296-1
Control Board Bracket
K75-36635
Control Board
K1D8388-1CC
Expansion Board
K1D8387-1CC
Standard Plastic Control Box
K74-39307-1
Outlet
K76-36296-1
Control Board Bracket
K75-36635
Control Board
K1D8388-1CC
Expansion Board
K1D8387-1CC
Standard Plastic Control Box
K74-39307-1
Outlet
K76-36296-1
Control Board Bracket
K75-36635
Control Board
K1D8388-1CC
Expansion Board
K1D8387-1CC
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX