The Trane Series R™ Helical Rotary Chiller RTWD100STD is a high-efficiency cooling solution designed for industrial applications. Known for its reliability and performance, this chiller utilizes advanced technology to optimize energy consumption while providing consistent temperature control. Ideal for large facilities, it ensures effective climate management.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Trane Series R™ Helical Rotary Chiller RTWD100STD
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Series R™ Helical Rotary Chiller Maintenance
Monthly Maintenance and Checks
Review operator log
Clean all water strainers in both the chilled and condensing water piping systems
Measure and log the subcooling
Measure and log the superheat
See “Refrigerant and Oil Charge Management,” p. 65. If chiller measurements vary significantly from values listed in Table 23, p. 65 and Table 24, p. 65, problems may exist with refrigerant and oil charge levels.
Contact local Trane service if measurements vary significantly?
1 Weekly Series R™ Helical Rotary Chiller Maintenance
Weekly Maintenance and Checks
After the unit has operated for approximately 30 minutes and the system has stabilized, check the operating conditions and complete the procedures below:
Log the chiller.
Check evaporator and condenser pressures with gauges and compare to the reading on the unit chiller.
Pressure readings should fall within the specified ranges listed in Table 23, p. 65 and Table 24, p. 65. If chiller measurements vary significantly from values listed, problems may exist with refrigerant and oil charge levels. Contact local Trane service.
Note: Optimal condenser pressure is dependent on condenser water temperature, and should equal the saturation pressure of the refrigerant at a temperature 2 to 5°F above that of leaving condenser water at full load.
Sign off on the weekly maintenance check.
1 Yearly Series R™ Helical Rotary Chiller Maintenance
WARNING: Hazardous Voltage! Failure to disconnect power before servicing could result in death or serious injury. Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Verify that no power is present with a voltmeter.
Shut down the chiller once each year to check the following:
Yearly Procedures:
Sign off on the yearly maintenance
3 Yearly Series R™ Helical Rotary Chiller Maintenance
Use a nondestructive tube test to inspect the condenser and evaporator tubes at 3-year intervals.
NOTE: It may be desirable to perform tube tests on these components at more frequent intervals, depending upon chiller application. This is especially true of critical process equipment.
Depending on chiller duty, contact a qualified service organization to determine when to conduct a complete examination of the unit to determine the condition of the compressor and internal components.
Nondestructive tube test passed?
Describe any issues found during the tube test
Was a complete examination of the unit conducted?
Describe the condition of the compressor and internal components
Sign off on the 3 Yearly Series R™ Helical Rotary Chiller Maintenance
Chemical Cleaning
Warning: This procedure requires trained personnel with PPE!
Name of the water treatment specialist consulted
Recommended cleaning solution
Materials used in the external circulation system
Quantity of the solution used
Duration of the cleaning period
Safety Precautions
Was safety gear used during the procedure?
Note: Chemical tube cleaning should always be followed by mechanical tube cleaning.
Access the parts list for your equipment in MaintainX.
Isolator RDP-4 Red [62] 2250 (1021)
X10140305-xx
Safety Hoist Ring M12x1.75
RNG01886
Isolator RDP-4 Red [62] 2250 (1021)
X10140305-xx
Safety Hoist Ring M12x1.75
RNG01886
Isolator RDP-4 Red [62] 2250 (1021)
X10140305-xx
Safety Hoist Ring M12x1.75
RNG01886
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX