MaintainX, an Autodesk company
EnterprisePricing
Lennox

Lennox Cooling Unit LCH072

Need answers fast?
Explore the manual using AI.

Lennox Cooling Unit LCH072
Lennox Cooling Unit LCH072

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Lennox Cooling Unit LCH072

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Lennox Cooling Unit LCH072

Lennox Cooling Unit LCH072

Create an account to install this asset package.

Maintenance Plans for Lennox Cooling Unit Model LCH072

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Condenser Coil Cleaning

Check mark

All-Aluminum Coils Cleaning

Check mark

Spray the coil steadily and uniformly from top to bottom with water

Check mark

Ensure pressure does not exceed 900 psi

Check mark

Ensure angle does not exceed 45 degrees

Check mark

Ensure nozzle is at least 12 inches from the coil face

Check mark

Check for fractures between the fins and refrigerant tubes

Check mark

Reduce pressure and work cautiously to prevent damage

Check mark

Fin/Tube Coils Cleaning

Check mark

Clean condenser coil with detergent or commercial coil cleaner

Run this procedureArrow right

Evaporator Coil Maintenance

Check mark

Inspection and Cleaning

Check mark

Inspect the evaporator coil for dirt and debris

Check mark

Clean the coil using mild detergent or commercial coil cleaner

Check mark

Flushing

Check mark

Flush the coil with water

Check mark

Flush the condensate drain with water

Check mark

Ensure the following are not wet during flushing

Check mark

Post Maintenance

Check mark

Is the area around the coil clean and dry?

Run this procedureArrow right

1 Monthly Condenser Coil Inspeciton

Check mark

All-Aluminum Coils

Check mark

Inspect monthly during the cooling season.

Check mark

Fin/Tube Coils

Check mark

Inspect monthly during the cooling season.

Run this procedureArrow right

Combustion Air Inducer Maintenance

Check mark

Preparation

Check mark

Shut off power supply and gas to unit

Check mark

Disassembly

Check mark

Remove the mullion on the right side of the heat section

Check mark

Disconnect pressure switch air tubing from combustion air inducer port

Check mark

Remove and retain screws securing combustion air inducer to flue box

Check mark

Remove vent connector

Check mark

Cleaning

Check mark

Clean inducer wheel blades with a small brush

Run this procedureArrow right

Filter Replacement

Check mark

Preparation

Check mark

Ensure the unit is not in operation before starting the filter replacement.

Check mark

Verify the correct filter size from table 32.

Check mark

Filter Removal

Check mark

Remove the temporary filters from the unit

Check mark

Filter Installation

Check mark

Install the approved filters according to local codes or appropriate jurisdiction

Check mark

Post Installation Check

Check mark

Are the new filters installed correctly and securely?

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Lennox

Explore Other Assets