Manual for Kohler Electric Generator Decision Maker MPAC 1500

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Kohler Electric Generator Decision Maker MPAC 1500

Kohler Electric Generator Decision Maker MPAC 1500

Create an account to install this asset package.

Maintenance Plans for Kohler Electric Generator Model Decision Maker MPAC 1500

Integrate maintenance plans directly into your work orders in MaintainX.

External Inspection

Check mark

Visual Inspection

Check mark

Check for any signs of vibration

Check mark

Inspect for leakage

Check mark

Check for excessive temperature

Check mark

Look for contamination or deterioration

Check mark

Cleaning

Check mark

Remove accumulations of dirt, dust, and other contaminants

Check mark

Ensure no compressed air is used for cleaning

Check mark

Hardware Maintenance

Run this procedureArrow right

Internal Inspection

Check mark

Preparation

Check mark

Disconnect all power sources

Check mark

Open the transfer switch enclosure door

Check mark

Inspect internal components

Check mark

Check for accumulations of dirt, dust, moisture, or other contaminants

Check mark

Inspect for signs of corrosion

Check mark

Check for worn, missing, or broken components

Check mark

Inspect for loose hardware

Check mark

Check wire or cable insulation for deterioration, cuts, or abrasion

Run this procedureArrow right

1 Yearly Electric Generator Maintenance

Check mark

Electrical System

Check mark

Check for signs of overheating or loose connections

Check mark

Check the contactor’s external operating mechanism for cleanliness; clean and relubricate if dirty

Check mark

Inspect wiring insulation for deterioration, cuts, or abrasion. Repair or replace deteriorated or damaged wiring

Check mark

Tighten control and power wiring connections to specifications

Check mark

Check the transfer switch’s main power switching contacts’ condition; clean or replace the main contacts or replace the contactor assembly as necessary

Check mark

Control System

Check mark

Test all indicators (LEDs) and all remote control systems for operation

Check mark

General Equipment Condition

Run this procedureArrow right

1 Monthly Electric Generator Maintenance

Check mark

General Equipment Condition

Check mark

Inspect the outside of the transfer switch for any signs of issues

Check mark

Check that all external hardware is in place and in good condition

Run this procedureArrow right

1 Monthly Automatic Control System Testing

Check mark

Verify the expected sequence of operations during transfer to emergency source

Check mark

Observe the indicator LEDs on the transfer switch

Check mark

Watch and listen for signs of excessive noise or vibration

Check mark

Verify the expected sequence of operations during retransfer to preferred source

Check mark

Verify the generator set shutdown after cooldown period

Check mark

Verify time delay in OFF position during transfer to standby source and back to preferred source

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.