The Ingersoll Rand SSR-EP100 is a high-performance air compressor designed for industrial applications. Known for its reliability and efficiency, this model ensures optimal air delivery while minimizing energy consumption, making it an ideal choice for various operational needs.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Ingersoll Rand Air Compressor SSR-EP100
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Air Filter Element Replacement
Time of change - when the panel mounted indicator lights up, or annually, when the coolant is changed. Indicator should be observed at full load.
Shut down the compressor.
Loosen wing nut on top of inlet filter housing. Lift cover up and away to expose element.
Carefully remove the old element to prevent dirt from entering the inlet valve. Discard old element.
Thoroughly clean the element housing and wipe all surfaces.
Install new element and inspect to insure that it has seated properly.
Install top of inlet filter housing.
Inspect the rubber seal on the retainer wing nut and replace seal if required.
Tighten wing nut.
2000 Hourly Coolant Filter Element Replacement
WARNING! Confirm all pressure is relieved from the compressor system and that the main electric disconnect switch is open and tagged to remain open.
Pressure relieved from the compressor system?
Main electric disconnect switch is open and tagged to remain open?
Place a suitable container under the filter housing drain valve which is located near the bottom of the housing.
Container placed under the filter housing drain valve?
Remove the bolt at the bottom of the housing. This will free the housing and element from the filter head. Remove the 'O' ring gasket.
Bolt and 'O' ring gasket removed?
Inspect the element and housing for foreign particles which have been trapped in the element and also for general overall condition - then discard the element and clean the housing.
Element and housing inspected and cleaned?
6 Monthly / 2000 Hourly Drive Motor Lubrication
Induction-type squirrel cage motor lubrication
The motor has anti-friction ball or roller bearings front and rear. At extended intervals they require relubrication.
The periods between re-greasings of the motor bearings can vary, primarily with the security of the service conditions under which the motor operates.
Select the type of motor
For severe duty - Dusty locations - High Ambients, reduce time intervals in table above to 1/3 the listed value.
Enter the hours of operation since last lubrication
Was the lubrication successful?
Sign off on the motor lubrication
8000 Hourly / 1 Yearly Lubricant Replacement
Warning: No drainage points should be opened until the compressor has been isolated electrically and all air pressure has been removed from the system.
Is the compressor isolated electrically and all air pressure removed from the system?
Warning: Extreme care should be exercised when draining the hot lubricant so that no possibility of injury to personnel exists.
Has the lubricant been drained soon after the compressor has been shut down?
Has a new filter element been installed?
Select the capacity of the compressor
Is the receiver level of lubricant up to the mid-point of the gauge glass?
Has the compressor been started and run for a short while?
Has the compressor been shut down and the lubricant level in the receiver checked?
Ball or Roller Bearings Lubrication
CAUTION! Grease should only be added when the motor is stopped and power disconnected.
Motor stopped and power disconnected?
When regreasing, stop motor and remove inlet and outlet plugs.
Inlet and outlet plugs removed?
Inlet grease gun fittings and spring-loaded outlets are arranged at each end on the motor housing. Use a hand lever type grease gun.
Hand lever type grease gun used?
Determine in advance the quantity of grease delivered with each stroke of the lever. Add grease in the following quantity: 3/4 cu. in. or 0.6 oz. (13.0 c.c. or 18 grams)
Quantity of grease delivered with each stroke of the lever
Do not expect grease to appear at the outlet, but if it does discontinue greasing at once.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX