MaintainX Asset Hub logo
EnterprisePricing
Ingersoll Rand

Ingersoll Rand Air Compressor HXP50–PE

Need answers fast?
Explore the manual using AI.

Ingersoll Rand Air Compressor HXP50–PE
Ingersoll Rand Air Compressor HXP50–PE

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Ingersoll Rand Air Compressor HXP50–PE

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Ingersoll Rand Air Compressor HXP50–PE

Ingersoll Rand Air Compressor HXP50–PE

Create an account to install this asset package.

Maintenance Plans for Ingersoll Rand Air Compressor Model HXP50–PE

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Air Compressor Maintenance

Check mark

Check the coolant level and replenish if necessary.

Check mark

Visual check of machine for any leaks, dust build up or unusual noise or vibration

Check mark

Report immediately, contact Ingersoll Rand authorized distributor for assistance if in doubt

Check mark

When compressor is receiver mounted

Check mark

Drain air receiver of condensate, or check that automatic drain is operating.

Check mark

Visual check condition of package pre–filter

Check mark

Blow clean if needed.

Check mark

Sign off on the daily air compressor maintenance

Run this procedureArrow right

1 Monthly / 100 Hourly Air Compressor Maintenance

Check mark

Remove and clean package pre–filter, replace if needed

Check mark

Check the cooler(s) for build up of foreign matter. Clean if necessary by blowing out with air or by pressure washing.

Check mark

COOLER CLEANING PROCEDURE

Check mark

1. Stop the machine, electrically isolate and vent all trapped pressure.

Check mark

2. Remove the top cover to obtain access to the cooler.

Check mark

3. Clean the cooler.

Check mark

4. Rebuild in reverse order.

Check mark

Check hoses and fittings for leaks – tighten as required.

Run this procedureArrow right

1 Yearly / 2000 Hourly Air Compressor Maintenance

Check mark

Warning: Always stop the machine, electrically isolate and vent all trapped pressure before starting any maintenance procedure.

Check mark

Is the air filter indicator locked into red position before the 2000 hour/1 year change out period?

Check mark

If yes, follow the steps below:

Check mark

Check the Condition of filter.

Check mark

Change the air filter if needed.

Check mark

Coolant Filter Change Procedure

Check mark

Loosen filter with the correct tool.

Check mark

Remove the filter from the housing.

Check mark

Place the old filter in a sealed bag and dispose of in a safe way.

Run this procedureArrow right

2 Yearly / 8000 Hourly Air Compressor Maintenance

Check mark

Change drive belt and gas spring.

Check mark

Replace the Ultra Coolant at whichever interval occurs first.

Check mark

COOLANT CHANGE PROCEDURE

Check mark

It is better to drain the coolant immediately after the compressor has been operating as the liquid will drain more easily and any contaminant will still be in suspension.

Check mark

1. Stop the machine, electrically isolate and vent all trapped pressure.

Check mark

2. Place a suitable container close to the drain valve.

Check mark

3. Slowly remove fill/vent cap.

Check mark

4. Remove plug from drain valve.

Check mark

5. Open the drain valve and drain coolant into container.

Run this procedureArrow right

4 Yearly / 16000 Hourly Air Compressor Maintenance

Check mark

Replace all hoses.

Check mark

Strip, clean and re–Grease motor bearings of ODP motors.

Check mark

Replace sealed bearing on IP55 motors.

Check mark

Fit replacement electrical contactor tips.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Ingersoll Rand

Explore Other Assets