Goodman Gas Furnace GMSS921004CNAA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Furnace Inspection
WARNING: HIGH VOLTAGE
Disconnect all power before servicing or installing the unit
Check the following furnace components for proper working order
Ignitor Handling Precautions
Was the ignitor handled with care?
Describe any issues encountered with the ignitor
Post Inspection
Were all necessary repairs or services performed?
Technician's Signature
Heating Performance Test
Preparation
Ensure all other gas appliances are turned off
Ensure the heating cycle has been in operation for at least fifteen minutes
Gas Meter Clocking
Record the time taken for the hand on the cubic foot dial to make one complete revolution
Calculate the cubic feet of gas consumed per hour using the gas rate chart
BTU Input Calculation
Enter the calorific value of the gas (BTU per cubic foot)
Calculate the BTU input by multiplying the cubic feet of gas consumed per hour by the calorific value
Burner Visual Check
Safety Warning
Turn on the furnace at the thermostat
Wait a few minutes for dust to settle
Burner Flame Check
Are the flames stable, soft, and blue with slightly orange tips?
Are the flames not curling, floating, or lifting off the ports?
2 Monthly Filter Replacement
WARNING: High Voltage
Disconnect all power sources
Check the type of filter
Clean the permanent filter
Replace the disposable filter
Ensure the new filter is of the same type and size
Reconnect all power sources
Verify system operation after filter maintenance
Electronic Air Cleaner Inspection
Pre-Inspection Setup
Ensure the air cleaner is installed in the correct position (not with the access door facing down).
Verify the air cleaner is located in the return air duct next to the blower compartment.
Electronic Air Cleaner Inspection
Inspect the accessibility of the electronic air cleaner for periodic inspection and cleaning.
Check the pre-filters for cleanliness and clean if necessary.
Inspect the electronic cells for cleanliness and clean if necessary.
Media Air Cleaner Inspection
Ensure the media air cleaner is accessible for periodic inspection and replacement of the filter cartridge.
Access the parts list for your equipment in MaintainX.
External Filter Rack Kit
EFR02
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
External Filter Rack Kit
EFR02
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
External Filter Rack Kit
EFR02
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX