Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Gardner Denver Base Mounted Compressor L90
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
125 Hourly Compressor Inspection
Danger: High voltage – Hazard of shock, burn, or death. Be careful with electricity: only work on screw compressors which are not powered.
Only for L90RS-L132RS: There is a risk of electric shock from charged capacitors! Disconnect the system from the mains and wait 10 minutes before touching electrical components.
Warning: Some parts of the system will still be pressurized after the system has been switched off. Small parts propelled at high speed by compressed air can penetrate the skin or destroy an eye.
Caution: Burn hazard – Hot surfaces. Be careful of the hot surfaces of machine parts when carrying out checks, making settings and doing maintenance.
Check for dirt accumulation on oil/aftercooler core faces and the cooling fan.
Clean the exterior fin surfaces of the cores by blowing compressed air carrying a nonflammable safety solvent, that will not damage aluminum in a direction opposite that of the cooling air flow.
Press the STOP button on the control panel and wait until the screw compressor comes to a stop and the screw compressor unit is depressurized.
Enter the pressure gauge reading
Relieve the screw compressor unit by slowly opening the screw plug (oil filling opening) with integrated air vent slots.
2000 Hourly / 6 Monthly Air Intake Filter Replacement
Danger! Only perform checks and carry out work on the screw compressor when the unit is out of operation, depressurized, and secured from being switched on again!
Is the unit out of operation and depressurized?
Is the unit secured from being switched on again?
Pull snap latch outward and remove housing base.
Detach air filter cartridge while slightly turning it.
Carefully insert new air filter cartridge in the housing.
Close air filter with housing base. The snap latches must click into position.
Sign off on the air filter replacement
2000 Hourly / 6 Monthly Compressor Maintenance
Danger
High voltage – Hazard of shock, burn, or death
Be careful with electricity: only work on screw compressors which are not powered.
Only for L90RS-L132RS: There is a risk of electric shock from charged capacitors! Disconnect the systemfrom the mains and wait 10 minutes before touching electrical components.
The power capacitors need this time to discharge.
Every 2000 hours operation or 6 months
1. Replace the oil filter element, air filter element, cool air inlet filter pad and control box filter (if app.) as indicated by the compressor controller, every 2000 hours or every 6 months, whichever occurs first.
Perform filter mat change as follows:
Remove the mounting screws.
2000 Hourly / 6 Monthly Oil Filter Cartridge Replacement
Danger! Air/oil under pressure will cause severe personal injury or death. Shut down the compressor, relieve the system of all pressure, disconnect, lockout and tagout the power supply to the compressor package before removing valves, caps, plugs, fittings, bolts and filters.
NOTICE!: Dispose of the oil filter cartridge properly - it is hazardous waste! Look for leaks!
Caution! Fire hazard and slip hazard! Do not spill any oil! Look for leaks! Immediately take care of any spilled oil!
Switch off the screw compressor unit, secure it against an accidental restart and ensure that it is depressurized.
Wait at least 5 minutes until the oil has settled, i.e. until the air has bubbled out.
Unscrew the oil filter cartridge with a suitable tool
Dispose of the oil filter cartridge properly
Lightly oil the seal of the new oil filter cartridge
Screw on the new oil filter cartridge and tighten by hand (see the notes on the oil filter cartridge)
4000 Hourly / 1 Yearly Compressor Maintenance
Danger
High voltage – Hazard of shock, burn, or death
Be careful with electricity: only work on screw compressors which are not powered.
Only for L90RS-L132RS: There is a risk of electric shock from charged capacitors! Disconnect the systemfrom the mains and wait 10 minutes before touching electrical components.
The power capacitors need this time to discharge.
Every 4000 hours operation or 12 months
1. Visually check for leakage on the shaft seal,replace as required.
The tool kit is required to change the oil seal. If the oil seal is a lip seal, the wear sleeve must always be replaced.
2. Replace lubricant every 8000 hours. Under adverse conditions, change more frequently. Flush system if required.
Access the parts list for your equipment in MaintainX.
Lubrication Oil
AEON 9000SP
Lubrication Oil
AEON 9000SP
Lubrication Oil
AEON 9000SP
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX