Atlas Copco Oxygen Generator OGP 2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
16000 Hourly/2 Yearly Oxygen Generator Maintenance
Safety Precautions: Close the generator's outlet valve and the air inlet valve and wait until machine working pressure is 0 bar. Switch off the generator. Always vent oxygen to the outside atmosphere. Avoid closing valves too fast as gas velocities in the oxygen net might become too high, and create a hazardous situation.
Generator fully depressurized and purged with air to remove all oxygen?
Checked for damaged wiring or loose connections, and re-tightened?
Checked for air leaks?
Replaced the in- and outlet filter cartridges?
Replaced the activated carbon of the filter?
Replaced the pneumatic valve(s) SV05. Used only oxygen approved grease?
Cleaned the filter of the electrical cabinet?
Replaced the pneumatic valves SV01 up to SV04?
1 Daily Controller Check
Safety Precautions: Close the generator's outlet valve and the air inlet valve and wait until machine working pressure is 0 bar. Switch off the generator. Always vent oxygen to the outside atmosphere. Avoid closing valves too fast as gas velocities in the oxygen net might become too high, and create a hazardous situation.
Is the machine working pressure at 0 bar?
Is the generator switched off?
Is the generator fully depressurized?
Is the oxygen vented to the outside atmosphere?
Are valves closed slowly to avoid high gas velocities?
Controller Check
Is the purity level acceptable?
Are there any alarms on the controller?
1 Yearly Oxygen Sensor Calibration
Safety Precautions
Generator's outlet valve and air inlet valve closed and machine working pressure is 0 bar?
Generator switched off?
Generator fully depressurized and purged thoroughly with air to remove all oxygen?
Oxygen vented to the outside atmosphere?
No smoking and use of open flames in the vicinity of the oxygen generator?
Valves closed slowly to avoid high gas velocities in the oxygen net?
Calibration Check
Generator set in Manual mode?
4000 Hourly/1 Yearly Oxygen Generator Maintenance
Safety Precautions: Close the generator's outlet valve and the air inlet valve and wait until machine working pressure is 0 bar. Switch off the generator. Always vent oxygen to the outside atmosphere. Due to fire hazard, smoking and the use of open flames are prohibited in the vicinity of the oxygen generator. Avoid closing valves too fast as gas velocities in the oxygen net might become too high, and create a hazardous situation.
Generator fully depressurized and purged with air to remove all oxygen before service or inspection?
Check for damaged wiring or loose connections, and re-tighten
Check for air leaks
Replace the in- and outlet filter cartridges
Replace the activated carbon of the filter
After maintenance activities, the service counter needs to be reset. Contact your supplier.
Sign off on the oxygen generator maintenance
5 Yearly Oxygen Sensor Replacement
Safety Precautions: Close the generator's outlet valve and the air inlet valve and wait until machine working pressure is 0 bar. Switch off the generator. Make sure the generator is fully depressurized and purge thoroughly with air to remove all oxygen before service or inspection. Always vent oxygen to the outside atmosphere. Avoid closing valves too fast. Smoking and the use of open flames are prohibited in the vicinity of the oxygen generator.
After maintenance activities, the service counter needs to be reset. Contact your supplier.
Shut off the outlet flow after the buffer tank. (BA08)
Close the ball valve (BA09) of the purity measurement line.
Shut down the generator (generator shows OFF).
Switch off the voltage.
Disconnect the oxygen sensor wiring from the oxygen analyzer in the electrical cabinet.
Disconnect the wiring of the oxygen analyzer in the electrical cabinet.
Remove the oxygen sensor and the oxygen analyzer from sampling system.
Access the parts list for your equipment in MaintainX.
Flow Sensor
CS VA420
Vessel
BF40PED11V
Flow Sensor
CS VA420
Vessel
BF40PED11V
Flow Sensor
CS VA420
Vessel
BF40PED11V
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX