Ferroli Electric Water Heater SG15SVE1.5
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Water Heater Exterior Cleaning
Safety Warnings
Ensure the electrical outlet is 220-240v a.c. 50/60Hz and connected with earth line.
Press the switch button and set the temperature knob to the required temperature.
Is the on/off indicator light on?
Ensure the water heater's automatic constant temperature control function is operational.
Check that the highest water temperature does not exceed 75℃.
Ensure the water valve on cold inlet is open during operation.
Verify that the drainpipe connected to the pressure release outlet is facing downward and open to atmosphere.
Confirm only the original safety valve from product packing is used and not adjusted.
1 Yearly Water Heater Cleaning
Safety Warnings
Ensure the electrical outlet is 220-240v a.c. 50/60Hz and connected with earth line.
Verify the on/off indicator lights when the switch button is pressed and the temperature-setting knob is turned.
Confirm the water heater's automatic constant temperature control function is operational.
Check that the highest water temperature does not exceed 75℃.
Ensure the water valve on cold inlet is open during operation.
Verify the drainpipe connected to the pressure release outlet is facing downward and open to atmosphere.
Confirm only the original safety valve from product packing is used and not adjusted.
Ensure any electrical component damage is checked by an authorized technician.
1 Monthly Water Heater Safety Valve Test
Safety Warnings
Ensure the electrical outlet is 220-240v a.c. 50/60Hz and connected with earth line.
Press the switch button and set the temperature knob to the required temperature. Confirm the on/off indicator lights up.
Verify the water heater's automatic constant temperature control function is operational.
Check that the highest water temperature does not exceed 75℃. Test water temperature with hands before use.
Ensure the water valve on the cold inlet is open during operation.
Confirm the drainpipe connected to the pressure release outlet is facing downward and open to the atmosphere.
Use only the original safety valve from the product packaging. Do not adjust the releasing pressure.
Ensure any electrical component damage is checked by an authorized technician.
Water Heater Empty Maintenance
Safety Warnings
Ensure the electrical outlet is 220-240v a.c. 50/60Hz and connected with earth line.
Is the on/off indicator light on after pressing the switch button and setting the temperature?
Does the heater automatically maintain constant temperature control?
Check that the water temperature does not exceed 75℃ before use.
Ensure the water valve on cold inlet is open during operation.
Verify that the drainpipe connected to the pressure release outlet is facing downward and open to atmosphere.
Confirm only the original safety valve from product packing is used and not adjusted.
Record any damage to electrical components for authorized technician inspection.
Water Heater Magnesium Anode Replacement
Safety Warnings
Ensure the electrical outlet is 220-240v a.c. 50/60Hz and connected with earth line.
Verify the on/off indicator lights when the switch button is pressed and the temperature-setting knob is turned to the required temperature.
Confirm the water heater's automatic constant temperature control function is operational.
Check that the highest water temperature does not exceed 75℃ and avoid direct body contact.
Ensure the water valve on the cold inlet is open during operation.
Verify the drainpipe connected to the pressure release outlet is facing downward and open to the atmosphere.
Confirm only the original safety valve from the product packing is used and its releasing pressure is not adjusted.
Ensure any electrical component damage is checked by an authorized technician.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX