MaintainX Asset Hub logo
EnterprisePricing
Fanem

Fanem Incubator C1186A

Need answers fast?
Explore the manual using AI.

Fanem Incubator C1186A
Fanem Incubator C1186A

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Fanem Incubator C1186A

Fanem Incubator C1186A

Create an account to install this asset package.

Maintenance Plans for Fanem Incubator Model C1186A

Integrate maintenance plans directly into your work orders in MaintainX.

1186 Controller Unit Panel Cleaning

Check mark

Warning: Ensure the incubator is disconnected from electric power before starting the cleaning or maintenance procedure.

Check mark

Incubator disconnected from electric power?

Check mark

Control Panel Removal

Check mark

Incubator turned off?

Check mark

Cables disconnected from the panel lateral?

Check mark

Lock levers pulled upwards?

Check mark

Control panel pulled out softly?

Check mark

Cleaning and/or Disinfection Tank - EMA Model

Check mark

Enter the amount of clean water added to the tank

Run this procedureArrow right

12 Monthly Incubator Maintenance

Check mark

Routine Checking Every 12 Months

Check mark

Change every 12 Months:

Check mark

Base Fixture made of atoxic PVC

Check mark

Oval Port fixture made

Check mark

Air Damper made of atoxic PVC

Check mark

Air Damper made of atoxic PVC

Check mark

Self-Extinguishable Foam

Check mark

Mattress Cover made of atoxic PVC;

Run this procedureArrow right

12 Monthly Rechargeable Battery Change

Check mark

9V BATTERY – Change the battery every 12 months

Check mark

The 1186 Neonatal Incubator control units have a NiCd - 9V - - - type rechargeable battery which has the function of feeding the power failure alarm in case of power break.

Check mark

This battery is auto-rechargeable with the normal use of the equipment and its useful life is estimated for 12 months and once this period has elapsed the battery must be substituted for a new original part.

Check mark

Attention: Danger of Explosion, do not use common or alkaline battery. Use only rechargeable battery FANEM. Re.: 092.100.026. Access and substitution of this battery must only be performed by a trained technician.

Check mark

In order to perform the battery substitution, one should unscrew the control unit front panel, actuating on the 4 lateral bolts of the controller unit, uncouple the front panel, remove the battery from its container and perform the substitution. The battery connector is polarized, thus eliminating the risk of inattentive connections.

Check mark

Battery charge: For the full operation of this battery, it should be totally charged. The battery charge is performed when the incubator is turned on and the initial charge time must be 10 hours.;

Run this procedureArrow right

3 Monthly Air Filter Change

Check mark

Warning: Disposable consumption, Air Filter. It must not be cleaned or placed with the dirty face to the internal side. It must be changed whenever completely dirty or at the maximum of every 3 months.

Check mark

Remove the Filter lid by rotating the fixing buttons at 900

Check mark

Remove the used Air Filter

Check mark

Clean and dry all filter accommodation surfaces

Check mark

Install the new filtering element and reinstall the rear panel.

Check mark

Attention: A dirty air filter may affect the O2 concentration and/or cause carbon dioxide accumulation in the interior of the incubator.

Check mark

Check if the filter is checked in a routine that is compatible with the conditions of location.

Check mark

Especially, if the incubator is used in an environment that is usually dusty, more frequent changes may be deemed necessary.

Check mark

Exclusive use with the 1186 neonatal Incubator

Run this procedureArrow right

6 Monthly Incubator Change

Check mark

Elastic Handle with Oval Port replaced

Check mark

Iris Sleeve replaced

Check mark

Sign off on the incubator change

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

Explore Other Assets