Fanem Incubator C1186A
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1186 Controller Unit Panel Cleaning
Warning: Ensure the incubator is disconnected from electric power before starting the cleaning or maintenance procedure.
Incubator disconnected from electric power?
Control Panel Removal
Incubator turned off?
Cables disconnected from the panel lateral?
Lock levers pulled upwards?
Control panel pulled out softly?
Cleaning and/or Disinfection Tank - EMA Model
Enter the amount of clean water added to the tank
12 Monthly Incubator Maintenance
Routine Checking Every 12 Months
Change every 12 Months:
Base Fixture made of atoxic PVC
Oval Port fixture made
Air Damper made of atoxic PVC
Air Damper made of atoxic PVC
Self-Extinguishable Foam
Mattress Cover made of atoxic PVC;
12 Monthly Rechargeable Battery Change
9V BATTERY – Change the battery every 12 months
The 1186 Neonatal Incubator control units have a NiCd - 9V - - - type rechargeable battery which has the function of feeding the power failure alarm in case of power break.
This battery is auto-rechargeable with the normal use of the equipment and its useful life is estimated for 12 months and once this period has elapsed the battery must be substituted for a new original part.
Attention: Danger of Explosion, do not use common or alkaline battery. Use only rechargeable battery FANEM. Re.: 092.100.026. Access and substitution of this battery must only be performed by a trained technician.
In order to perform the battery substitution, one should unscrew the control unit front panel, actuating on the 4 lateral bolts of the controller unit, uncouple the front panel, remove the battery from its container and perform the substitution. The battery connector is polarized, thus eliminating the risk of inattentive connections.
Battery charge: For the full operation of this battery, it should be totally charged. The battery charge is performed when the incubator is turned on and the initial charge time must be 10 hours.;
3 Monthly Air Filter Change
Warning: Disposable consumption, Air Filter. It must not be cleaned or placed with the dirty face to the internal side. It must be changed whenever completely dirty or at the maximum of every 3 months.
Remove the Filter lid by rotating the fixing buttons at 900
Remove the used Air Filter
Clean and dry all filter accommodation surfaces
Install the new filtering element and reinstall the rear panel.
Attention: A dirty air filter may affect the O2 concentration and/or cause carbon dioxide accumulation in the interior of the incubator.
Check if the filter is checked in a routine that is compatible with the conditions of location.
Especially, if the incubator is used in an environment that is usually dusty, more frequent changes may be deemed necessary.
Exclusive use with the 1186 neonatal Incubator
6 Monthly Incubator Change
Elastic Handle with Oval Port replaced
Iris Sleeve replaced
Sign off on the incubator change
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX