Dunham-Bush Rotary Screw Water Chiller WCFX48
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Chiller Inspection
Check water treatment system components
Wipe down external surfaces of unit
Control Panel Inspection
Shut unit down and open main disconnect
Inspect control panel for loose wires, burned contacts, and signs of overheated wires
Unit Restart and Performance Check
Restart unit
Check performance of controls and time rate of loading and unloading
Is the refrigerant charge level in the flash tank feed line sight glass proper?
1 Yearly Oil Replacement
Pre-replacement Checks
Check the current oil level in the compressor
Is the oil return visible in the compressor?
Oil Replacement Process
Shut down the compressor
Drain the old oil from the compressor
Refill the compressor with new oil
Post-replacement Checks
Is the oil level within the recommended range after replacement?
1 Yearly Vessels Water Side Cleaning
Performance Data Recording
Record full load performance data on the log sheet
Approach Temperature Check
Enter the current approach temperature for the evaporator
Enter the current approach temperature for the condenser
Is the approach temperature more than 2°F above the clean condition?
Chemical Cleaning
Have water treatment specialists recommended chemicals for cleaning?
Rinse the system thoroughly after chemical cleaning
Electrical Malfunction Inspection
Phase Control Relay Inspection
Has the phase control relay tripped?
Did the phase control relay trip again after resetting?
Call your electric utility to investigate the problem
Circuit Breaker and Motor Overload Relay Inspection
Has the circuit breaker or motor overload relay tripped?
Do not reset and try to run the compressor again
Head Gasket Inspection
Visual Inspection
Inspect for physical disfigurement of the gasket
Check for signs of deterioration
Decision Making
Does the gasket need renewal based on inspection results?
Post Inspection
Document the inspection results
Inspector's signature
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX