MaintainX Asset Hub logo
EnterprisePricing
Donaldson Torit

Donaldson Torit Mist Collector DMC-MMB

Need answers fast?
Explore the manual using AI.

Donaldson Torit Mist Collector DMC-MMB
Donaldson Torit Mist Collector DMC-MMB

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Donaldson Torit Mist Collector DMC-MMB

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Donaldson Torit Mist Collector DMC-MMB

Donaldson Torit Mist Collector DMC-MMB

Create an account to install this asset package.

Maintenance Plans for Donaldson Torit Mist Collector Model DMC-MMB

Integrate maintenance plans directly into your work orders in MaintainX.

Junction Box Maintenance

Check mark

Remove the junction box cover plate

Check mark

Attach the ground wire to the ground terminal

Check mark

Attach the three hot wires to the remaining terminals

Check mark

Replace junction box cover plate

Check mark

Sign off on the junction box maintenance

Run this procedureArrow right

Third-Stage Filter Cartridge Replacement

Check mark

Warning: Replace the second-stage filter wrap and third-stage filter cartridge at the same time for easy maintenance.

Check mark

Filter cartridge removed

Check mark

Upload a photo of the removed filter cartridge

Check mark

New filter and wrap placed on the filter retention platform, gasket side up

Check mark

Filter slid back as far as it will go and centered side-to-side

Check mark

Filter retention lever lifted up and access door closed

Check mark

Sign off on the filter cartridge replacement

Run this procedureArrow right

Drain Collection Container Maintenance

Check mark

Turn unit OFF

Check mark

Remove the container by unscrewing the container from the cap

Check mark

Clean the container

Check mark

Clean the faucet

Check mark

Reinstall the container

Check mark

Note: Close the faucet before turning the collector back ON

Check mark

The optional drain collection container is available for use with an impact separator ONLY. A semi-clear one-gallon plastic container attached to the bottom of the impact separator collects small particles and coolant

Check mark

Install the container onto the bottom of the impact separator

Check mark

The container’s faucet must be closed when the unit is in operation

Run this procedureArrow right

Mist Collector Start-Up Check

Check mark

Warning: Electrical work during installation must be performed by a qualified electrician and comply with all applicable national and local codes.

Check mark

Turn power off and lock out electrical power sources before performing service or maintenance work.

Check mark

Check that the collector is clear and free of all debris before starting.

Check mark

Do not install in classified hazardous atmospheres without an enclosure rated for the application.

Check mark

Optional fans over 600 lbs must be independently supported.

Check mark

Check all electrical connections for tightness and contact.

Check mark

Motor and fan should be wired for clockwise rotation when viewed from the back of the motor.

Check mark

Warning: Do not interchange a power lead with the ground wire. Severe damage or personal injury may result.

Check mark

All access panels should be sealed and secure.

Run this procedureArrow right

Second-Stage Filter Wrap Replacement

Check mark

⚠️ WARNING: Use proper safety and protective equipment when removing contaminants and filters. Dirty filters may be heavier than they appear. Use care when removing filters to avoid personal injury.

Check mark

Note: Replace the second-stage filter wrap and third-stage filter cartridge at the same time for easy maintenance.

Check mark

Remove the filter cartridge by pulling the filter retention lever out and down to a horizontal position. Remove cartridge from unit.

Check mark

Pull wrap from filter cartridge and dispose of properly.

Check mark

Install new wrap, aligning the top of the wrap to the top of the cartridge and fasten securely with hook and loop fastener.

Check mark

Replace filter cartridge and secure with filter retention mechanism.

Check mark

⚠️ NOTICE: Do not operate the collector without the second-stage filter wrap installed. Significant reduction in filter cartridge life may result.

Check mark

Sign off on the filter wrap replacement

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Donaldson Torit

Explore Other Assets