MaintainX Asset Hub logo
EnterprisePricing
Donaldson Torit

Donaldson Torit Dust Collector UMA 150

Need answers fast?
Explore the manual using AI.

Donaldson Torit Dust Collector UMA 150
Donaldson Torit Dust Collector UMA 150

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Donaldson Torit Dust Collector UMA 150

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Donaldson Torit Dust Collector UMA 150

Donaldson Torit Dust Collector UMA 150

Create an account to install this asset package.

Maintenance Plans for Donaldson Torit Dust Collector Model UMA 150

Integrate maintenance plans directly into your work orders in MaintainX.

Dust Collector Check

Check mark

CAUTION:

Check mark

- Use proper equipment and adopt all safety precautions needed for servicing equipment.

Check mark

- Use appropriate access equipment and procedures. Note the standard collector is not equipped with access platforms unless noted on the specification drawings.

Check mark

- Electrical service or maintenance work must be performed by a qualified electrician and comply with all applicable national and local codes.

Check mark

- Turn power off and lock out all power before performing service or maintenance work.

Check mark

- Do not install in classified hazardous atmospheres without an enclosure rated for the application.

Check mark

Operational Checklist

Check mark

1. Monitor the physical condition of the collector and repair or replace any damaged components. Routine inspections will minimize downtime and maintain optimum system performance. This is particularly important on continuous-duty applications.

Check mark

2. Monitor pressure drop across filters. Abnormal changes in pressure drop may indicate a change in operating conditions and possibly a fault to be corrected.

Run this procedureArrow right

Dust Collector Start-Up Check

Check mark

CAUTION: Electrical work during installation, service or maintenance must be performed by a qualified electrician and comply with all applicable national and local codes.

Check mark

Turn power off and lock out all power before performing service or maintenance work.

Check mark

Check that the collector is clear and free of all debris before starting.

Check mark

Do not install in classified hazardous atmospheres without an enclosure rated for the application.

Check mark

Check all electrical connections for tightness and contact.

Check mark

Check for proper rotation on all motors.

Check mark

CAUTION: Do not look into fan outlet to determine rotation. View the fan rotation through the back of the motor.

Check mark

Check that the exhaust plenum is free of tools or debris before checking blower/fan rotation.

Check mark

Stand clear of exhaust to avoid personal injury.

Run this procedureArrow right

Filter Service

Check mark

CAUTION:

Check mark

- Use proper safety and protective equipment when removing contaminants and filters.

Check mark

- Dirty filters may be heavier than they appear.

Check mark

- Use care when removing filters to avoid personal injury and/or property damage.

Check mark

- Turn power off and lock out all power before performing service or maintenance work.

Check mark

- Do not operate with missing or damaged filters.

Check mark

Filter Removal

Check mark

1. Turn power to collector OFF. Open or remove the filter access door.

Check mark

2. Lower the retention handles in the bag chamber (for UMA 40 model size, loosen wing nuts on top of clean air plenum until filter frame releases from seal gasket).

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Donaldson Torit

Explore Other Assets