Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Water Chiller WSC100
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Condenser Temperature Approach Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Enter the leaving water temperature
Enter the saturated refrigerant temperature
Calculate and enter the approach temperature (subtract saturated refrigerant temperature from leaving water temperature)
Note: Daikin's high efficiency heat exchangers have very low design approach temperatures, in the order of one to one and one half degrees F.
Is the approach temperature within the normal range (1-1.5 degrees F)?
If the approach temperature is not within the normal range, it may indicate excessive tube fouling.
Enter the condenser pressure drop
Is the condenser pressure drop within the normal range?
1 Monthly Evaporator Temperature Approach Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Enter the leaving water temperature
Enter the saturated refrigerant temperature
Calculate the approach temperature (subtract saturated refrigerant temperature from leaving water temperature)
Is the approach temperature within the normal range (1 to 1.5 degrees F)?
If the approach temperature is not within the normal range, excessive tube fouling could be present.
Enter the condenser pressure drop
Is the condenser pressure drop within the normal range?
If the condenser pressure drop is not within the normal range, report the issue to the maintenance team.
1 Monthly Suction Line Temperature Check
Refrigerant Cycle Maintenance
Maintenance of the refrigerant cycle includes maintaining a log of the operating conditions, and checking that the unit has the proper oil and refrigerant charge.
Oil pressure
Suction pressure
Discharge pressure
Condenser water temperature
Chiller water temperature
The suction line temperature at the compressor should be taken at least once a month.
Suction line temperature at the compressor
1 Weekly Refrigerant Leak Test
Warning: Do not use oxygen or a mixture of R-22 and air to build up pressure as an explosion can occur causing serious personal injury.
Enter the initial pressure of the system in psig
Enter the pressure after adding refrigerant in psig
Enter the pressure after adding dry nitrogen in psig
Leak test with an electronic leak detector passed?
Water flow through the vessels maintained during the procedure?
Any leaks found in welded or brazed joints?
Was it necessary to replace a gasket?
If any leaks are found in welded or brazed joints, or it is necessary to replace a gasket, relieve the test pressure in the system before proceeding.
1 Yearly Chiller Shutdown
Seasonal Servicing
Is the chiller subject to freezing temperatures?
If yes, drain the condenser and chiller of all water.
Did you use dry air to force all water out of the condenser?
Did you remove the condenser heads?
Warning: Water left in the piping and vessels can rupture these parts if subjected to freezing temperature.
Did you circulate antifreeze through the water circuits?
Take measures to prevent the shutoff valve in the water supply line from being accidentally turned on.
Did you remove the pump drain plug in the water pump?
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX