MaintainX Asset Hub logo
EnterprisePricing
Daikin

Daikin Indoor Cooling/Heating Unit FXAQ07PVJU

Need answers fast?
Explore the manual using AI.

Daikin Indoor Cooling/Heating Unit FXAQ07PVJU
Daikin Indoor Cooling/Heating Unit FXAQ07PVJU

The Daikin Indoor Cooling/Heating Unit FXAQ07PVJU is a versatile HVAC solution designed for efficient climate control in residential and commercial spaces. This unit offers reliable heating and cooling performance, ensuring optimal comfort throughout the year. Experience energy efficiency and advanced technology with Daikin's trusted model.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Indoor Cooling/Heating Unit FXAQ07PVJU

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Indoor Cooling/Heating Unit FXAQ07PVJU

Daikin Indoor Cooling/Heating Unit FXAQ07PVJU

Create an account to install this asset package.

Maintenance Plans for Daikin Indoor Cooling/Heating Unit Model FXAQ07PVJU

Integrate maintenance plans directly into your work orders in MaintainX.

Electronic Expansion Valve Coil Check

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Electronic Expansion Valve Coil checked

Check mark

Remove the connector for electronic expansion valve (X7A) from PCB

Check mark

Measure the resistance value between pins

Check mark

No continuity between White and Yellow

Check mark

Resistance value between White and Orange

Check mark

Resistance value between White and Orange is approx. 300 Ω

Check mark

Resistance value between White and Red

Check mark

Resistance value between White and Red is approx. 150 Ω

Run this procedureArrow right

Heat Recovery System Maintenance

Check mark

Check for High Pressure in cooling

Check mark

Check for High Pressure in heating

Check mark

Check Thermistor (p. 295)

Check mark

Check Pressure Sensor (p. 298)

Check mark

Check for broken wire of the relay wire (p.299)

Check mark

Procedure for checking outdoor-outdoor unit transmission wiring for broken wires

Check mark

Procedure for checking indoor-outdoor unit transmission wiring for broken wires

Check mark

Check Fan Motor Connector (Power Supply Cable) (p.300)

Check mark

Check Fan Motor Connector (Signal Cable) (p.300)

Run this procedureArrow right

Heat Recovery System Vacuuming/Dehydration Maintenance

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Choose the type of vacuuming and dehydration

Check mark

Vacuum pump enables vacuuming down to –100.7 kPa (–14.6 psi)?

Check mark

Enter the vacuum level after 2 hours of evacuation

Check mark

Did the vacuum level reach –100.7 kPa (–14.6 psi) after 2 hours?

Check mark

Enter the vacuum level after additional 1 hour of evacuation if needed

Check mark

Did the vacuum level reach –100.7 kPa (–14.6 psi) after 3 hours?

Check mark

Did the leak tests pass?

Check mark

Enter the vacuum level after leaving the compressor in vacuum state for 1 hour

Run this procedureArrow right

Power Transistor Check

Check mark

Warning: Ensure power is OFF before starting the procedure

Check mark

Power OFF

Check mark

All wiring removed from the PCB

Check mark

Type of multimeter prepared

Check mark

Power supply turned OFF and 10 minutes or more have passed

Check mark

Measurement mode for analog multimeter

Check mark

Measurement mode for digital multimeter is diode check mode

Check mark

Sign off on the power transistor check

Run this procedureArrow right

Pressure Check

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Enter the compressor capacity control

Check mark

Refer to Compressor PI control for details

Check mark

Low pressure protection control functional?

Check mark

Hot gas bypass control functional?

Check mark

Enter the superheated degree control of indoor unit electronic expansion valve

Check mark

Enter the superheated degree control of outdoor unit heat exchanger

Check mark

Sign off on the pressure check

Run this procedureArrow right

Parts for Daikin Indoor Cooling/Heating Unit FXAQ07PVJU

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Junction Pipe Kit

KHRP26A250T

Junction Pipe Kit

KHRP26A250T

Junction Pipe Kit

KHRP26A250T

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets